STIEBEL ELTRON HUV 1 Скачать руководство пользователя страница 2

operAtion 
generAl informAtion

10 |  

HUV 1/2/65/80

1.  General information

This accessory installation guide is aimed at specialist technicians. 

For installing the heat pump or similar items, see the additional 

operating and installation instructions.

 

Please read

Read these instructions carefully before use and keep 

them in a safe place. If you pass on the equipment to 

another user, give them the instructions as well.

1.1  Explanation of symbols

Symbols in the documentation:

This documentation contains symbols and highlights. These have 

the following meanings:

 

Beware of injury

Indication of possible risk of injury to the technician or 

user, and possible damage to the device.

 

Beware of electrocution

 

 

Beware of burns and scalding

 

!

 

Beware of damage

Indicates a potentially dangerous situation which might 

occur while installing or operating the device and could 

damage the device or cause environmental or financial 

harm.

 

Please read

Read these instructions carefully before use and keep 

them in a safe place. If you pass on the equipment to 

another user, give them the instructions as well.

2.  Safety

2.1  Proper use

The 3-way switching valve distributes and regulates the flow in 

STIEBEL ELTRON or Tecalor heat pump systems. Any different or 

extended use is considered improper, especially use with other 

media to be heated. Proper use also includes observing the instal-

lation instructions. Only use the device for the purpose stated by 

the manufacturer and do not make any modifications to it.
This appliance is designed for domestic use. It can be used safely 

by untrained persons. The appliance can also be used in a non-

domestic environment, e.g. in a small business, as long as it is 

used in the same way.

2.2  Safety instructions

Observe the following safety instructions and regula-

tions.

Heat pump systems and accessories may only be installed by a 

recognised specialised company.
The qualified technician is responsible for observing all applicable 

regulations during installation and commissioning.
Only operate the device when it is fully installed with all its safety 

equipment.

 

Beware of electrocution

Switch off the power supply immediately if cables are 

damaged. Make sure it is secured against being switched 

on again unintentionally.

 

Beware of electrocution

Make sure all cable entries are fitted with the appropri-

ate protection class.

 

Beware of burns and scalding

Before working on the system, let the pipes on the rel-

evant section cool down as necessary and reduce the 

system pressure to ambient pressure.

 

Beware of injury

The appliance may be used by children aged 8 and up 

and persons with reduced physical, sensory or mental 

capabilities or a lack of experience provided that they 

are supervised or they have been instructed on how to 

use the appliance safely and have understood the resul-

ting risks. Children must never play with the appliance. 

Children must never clean the appliance or perform user 

maintenance unless they are supervised.

!

 

Beware of damage

The 3-way switching valve is designed for use in STIEBEL 

ELTRON or Tecalor heat pump systems and may not be 

used for applications outside the stated range, particu-

larly in aircraft or other means of transport.

3.  Device description

3.1  Overview of models and combination options

model

order no.

HUV 1

247420

HUV 2

223391

HUV 65

227425

HUV 80

227426

3.2  Scope of delivery

 

- 3-way switching valve

 

- Servo drive

 

- 3 x counter screws G1 

1

/

2

” x 1” (HUV 1 only)

 

- 3 x counter screws G2 

3

/

4

“ x 2“ (HUV 2 only)

The servo drive is delivered already fitted to the 3-way switching 

valve.

Содержание HUV 1

Страница 1: ...d Installation Operating and installation Utilisation et Installation Gebruik en Installatie 3 Wege Umschaltventil 3 way switching valve Soupape d inversion 3 voies Drieweg omschakelklep HUV 1 HUV 2 H...

Страница 2: ...ong as it is used in the same way 2 2 Safety instructions Observe the following safety instructions and regula tions Heat pump systems and accessories may only be installed by a recognised specialised...

Страница 3: ...al The valve opens by turning clockwise and closes by turning anticlockwise factory setting HUV 65 HUV 80 only The lift drives are regulated by a 3 point control system and move the closing element wh...

Страница 4: ...he tappet facing down Permissible installation positions 90 90 C26_03_01_0998 4 2 Hydraulic connection Beware of damage The conditions in VDI 2035 regarding water quality must be complied with So that...

Страница 5: ...tion diagram open closed control a b 1 2 3 N L a a b b D0000043142 1 blue 2 brown 3 white 5 Maintenance The 3 way switching valves with integrated servo drive require no maintenance They do not contai...

Страница 6: ...ed II double insulated II double insulated IP rating IP54 IP54 IP54 IP54 Dimensions Length mm 84 5 131 5 290 310 Weights Weight kg 1 65 4 8 16 3 22 5 Values Permissible medium H2O H2O H2O H2O Permissi...

Страница 7: ...ssued by those subsidiaries Such warranties are only granted if the subsidiary has issued its own terms of warranty No other warranty will be granted We shall not provide any warranty for appliances a...

Страница 8: ...ergissingen en technische wijzigingen Salvo error o modificaci n t cnica R tt till misstag och tekniska ndringar f rbeh lls Excepto erro ou altera o t cnica Zastrze one zmiany techniczne i ewentualne...