InStaLLatIOn
Shutting down
Scanning the error menu
The error menu only appears if the appliance has a fault.
26
�02
�02
�1
31
3�
1
2
3
4
1 Electronic assembly symbol
f
f
Replace the electronic assembly.
2 Safety circuit symbol
f
f
Check the AE 3 connection; replace the AE 3 if required.
3 Outlet sensor symbol
f
f
Check the outlet sensor connection; replace the outlet sensor
if required.
4 Motorised valve symbol
f
f
Check the motorised valve connection; replace the motorised
valve if required.
Scanning the control menu
26
�0
2�
02
�1
31
2�
1
2
3
4
1 Inlet temperature symbol,
shows the current inlet temperature (shows 1.0 °C if the sen-
sor is faulty).
2 Outlet temperature symbol,
shows the current outlet temperature (shows 65.0 °C if the
sensor is faulty).
3 Flow rate symbol,
shows the current flow rate.
4 Power consumption symbol,
shows the current power consumption.
Scanning the appliance data menu
26
�02
�02
�1
31
4�
1
2
3
4
1 Service code symbol,
information for service engineers.
2 Symbol for power supply runtime,
accumulated runtime in days.
3 Heating hours symbol,
accumulated heating time in hours.
4 Maximum output symbol
The value shown may diverge by several kW from the rated
output if mains voltages other than 400 V prevail.
Setting the anti-scalding protection
Use the anti-scalding protection in places such as nurseries and
hospitals. If anti-scalding protection is selected, the childproofing
adjustment will be limited (see chapter "Appliance settings").
26
�02
�02
�1
30
1�
Setting range: 21 - 60 °C
Recommended setting 43 °C
Note
The anti-scalding protection setting can only be modified
by your contractor. Simultaneously pressing the M + i key
will not change the setting.
13. Shutting down
f
f
Isolate all poles of the appliance from the power supply.
f
f
Drain the appliance (see chapter "Maintenance").
14. troubleshooting
WARNING Electrocution
In order to check the appliance, it must be supplied with
power.
Plug-in connections on the PcB
26
�02
�02
�1
34
3
1
5
6
7
2
3
4
1 Diagnostic traffic light (3 LEDs)
2 Flow rate sensor DFE
3 Motorised valve
4 High limit safety cut-out STB
5 Outlet sensor NTC
6 Set temperature transducer
7 Safety switch AE 3; plug-in connection secured with locking
tab.