OpErATiON
Settings and displays
EN
GL
ISH
www.stiebel-eltron.com
DHE AU |
7
4.9.2 Parameter menu
menu Description
Selectable display |
setting
Explanations
Symbol |
display
P 1
ECO water and energy
saving function
OFF | ECO1 | ECO2 | ECO3
The ECO function enables you to limit the flow rate to a maximum
value.
Flow rate limit:
8 l/min with "ECO1" | 7 l/min with "ECO2" | 6 l/min with "ECO3" | No
flow rate limit with "OFF".
| | |
P 2
Temperature limit Tmax
OFF | 20.0 | 20.5 ... °C or
68 | 69 ... °F
The temperature limit allows you as a user to restrict the adjustable
set temperature at the appliance to a maximum value. Check that the
upper temperature limit has been correctly applied.
Your qualified contractor can set an additional temperature limit for
anti-scalding protection. This temperature then dictates the upper
limit of the setting range for the temperature limit function.
P 3
Wellness showers
OFF | Pro1 | Pro2 | Pro3 |
Pro4
The Wellness shower program lets you choose from 4 different alter-
nating shower programs.
WW = domestic hot water, KW = cold water, min = minutes, sec = sec-
onds
- 1 Cold prevention
To strengthen the body, we recommend finishing off with a cold
shower; this will trigger a reflex in the body to warm up.
WW
KW
3 min
- 2 Winter refreshment
An invigorating end to a winter shower with a final warm-up.
WW
KW
3 min
10 sec
10 sec
10 sec
10 sec
WW
- 10 °C | 50 °F
- 3 Summer fitness program
A quick contrast shower to increase fitness with a final warm-up.
WW
KW
3 min
10 sec
10 sec
10 sec
10 sec
- 4 Circulation boost program
Shower your arms and legs with cold water to boost circulation. Spray
from the hands and feet towards the body. You can then repeat this
process with hot water.
WW
KW
3 min
30 sec
20 sec
30 sec
20 sec
P 4
Automatic water volume
control – set the volume
in the selected unit
OFF | 5 | 10 | ... 200 l or
2 ... 52 gal
With the automatic water volume control, you can preselect a volume
of water, e.g. for filling a bathtub. When the preselected water volume
is reached, the automatic control reduces the flow rate. The automatic
water volume control must be enabled on each occasion prior to fill-
ing the bath.
Example, filling a bath with 80 litres (21 gallons): When the bath has
been filled with 80 litres (21 gallons), the control automatically reduc-
es the flow rate to 4 l/min (1 gpm).
P 5
Temperature unit
C | F
Select the temperature unit for all settings.
°C | °F
P 6
Volume unit
L | GAL
Select the volume unit for all settings.
l | gal
P 7
Time format
24h | 12h
Select time format.
P 8
Time setting
--:--
You can set the time using the 12 or 24 hour clock:
- 12 hours from 00:00 - 11:59 = AM | 11:59 - 00:00 = PM
- 24 hours from 00:00 to 23:59
After a power cut, the time needs to be set again.
AM | PM (only
for 12h)
P 9
Operating lock
ON | OFF
You can set the operating lock to "ON" or "OFF".
To disable the set operating lock:
f
Press and hold "i" for more than 10 seconds.
(only when
ON)
P 10
Reset to factory settings
Reset (
)
You can restore the appliance to its factory settings. "rSEt" is shown
on the display.
f
Press "1" and "2" simultaneously and hold for longer than 5 sec-
onds. The display switches to "On" to confirm the reset.
f
To confirm "On", press and hold "i" for more than 5 seconds.
Содержание DHE 18 AU