17.6 Data
tables
DHC-E 3/3.5-1 Trend
DHC-E 4/6-2 Trend
Item no.
200057
200061
Electrical data
Phase (50/60
Hz
)
1/N/GND
1/N/GND | 2/GND
Rated voltage
120
V
240
V
208
V
Rated output
1
, jumper position 1 [low] / 2 [high]
3.0
kW
/ 3.5
kW
3.8
kW
/ 6.0
kW
2.9
kW
/ 4.5
kW
Amperage draw, jumper position 1 [low] / 2 [high]
25
A
/ 29.2
A
15.8
A
/ 25
A
13.9
A
/ 21.7
A
Min. recommended circuit breaker size
2
, jumper position 1 [low] / 2 [high]
25
A
/ 30
A
20
A
/ 25
A
15
A
/ 25
A
Min recommended wire size
3
(copper), jumper position 1 [low] / 2 [high]
10/2
AWG
/ 10/2
AWG
12/2
AWG
/ 10/2
AWG
14/2
AWG
/ 10/2
AWG
Min. resistivity ρ15 ≥
1100 Ω cm
Max. conductivity
ı
15 ≤
910 μS/cm
Connections
Water connections
½˝
NPT
Application limits
Maximum permissible pressure
145
psi
(1
MPa
)
Maximum inlet temperature for reheating
131
°F
(55
°C
)
Maximum inlet temperature
149
°F
(65
°C
)
User selectable temperature range
68–140
°F
(20–60
°C
)
Internal anti-scalding protection temperature limiter values
100/109/122/
140
°F
(38/43/50/
60
°C
)
Hydraulic data
Minimum water flow to activate unit
0.264
gal
(1.0
l/min
)
Nominal water volume
0.07
gal
(0.277
l
)
Other
Type of installation
Over-sink/under-sink
Protection class
1
Insulating block
Glass-reinforced polyamide
Heating system
Direct Coil
Cover and back panel
Plastic
Color
White
Dimensions
Height
14
1
/
8
˝ (360
mm
)
Width
8˝ (202
mm
)
Depth
4
5
/
16
˝ (109
mm
)
Weights
Weight
5.5
lbs
(2.5
kg
)
DHC-E 3/3.5-1 Trend ships with a 0.5 gpm (1.9 l/min) pressure compensating flow-reducer/aerator that must be installed.
DHC-E 4/6-2 Trend ships with 2 x 0.5 gpm (1.9 l/min) and a 1.0 gpm (3.8 l/min) pressure compensating flow-reducer/aerator that must be installed. See section 11.3, “Aerator
installation at connected faucet,” pg. 17 for more information.
1
Factory default setting is jumper position 2 [high]
2
Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A circuit breakers.
3
Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3% under load.
These are our recommendations. Check local codes for compliance if necessary.