Operation
Operation
20
| DHB-E SLi | A electronic
www.stiebel-eltron.com
4. Operation
DHB-E ... SLi
30
60
45
35
40
50
55
2
6
_0
2_0
2
_1
3
8
1
DHB-E ... A
30
50
40
35
45
26
_0
2
_02
_1
3
8
2
Should the outlet temperature fail to reach the required level,
when the draw-off valve is fully opened, and the temperature
selector has been set to maximum, then more water flows through
the equipment, than can be heated by the internal heater car-
tridge.
f
Reduce the flow rate with the draw-off valve.
4.1 Outlet
capacities
Subject to season, different maximum mixed water or outlet ca-
pacities can result from varying cold water temperatures. For
further information, see chapter Specification.
4.2 Thermostatic
valve
We recommend adjusting the appliance to the maximum tem-
perature setting.
4.3
Temperature limit/Anti-scalding protection
The maximum outlet temperature for the appliance can be limited
to 43 °C. Refer in this case to your local heating contractor..
5. Cleaning, care and maintenance
f
Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
Maintenance work, such as checking the electrical safety, must
only be carried out by a heating contractor.
6. Troubleshooting
!
Material damage
Following an interruption of the water supply the appli-
ance must be recommissioned by carrying out the follow-
ing steps, in order to prevent the destruction of the bare
wire heating system.
f
Disconnect the appliance from the power supply by
removing the fuses/tripping the MCBs.
f
Open the tap until the appliance and its upstream
cold water inlet line are free of air.
f
Switch the mains power back ON again.
Fault
Cause
Remedy
The appliance will
not start in spite of
a fully open DHW
valve.
There is no power.
Check the fuse/MCB in your
fuse box/distribution panel.
The flow rate is too low.
The jet controller in the tap
or shower head is scaled
up or contaminated.
Clean and/or descale the
jet controller or shower
head.
The heater is faulty.
Telephone your contractor.
Required temper-
ature 45 °C is not
achieved.
The water supply has been
interrupted.
Cold water inlet tempera-
ture is 45 °C.
Vent the appliance and cold
water inlet pipe of air.
Reduce the cold water inlet
temperature.
If you cannot remedy the fault, notify your heating contractor. To
facilitate and speed up your enquiry, please provide the serial
number from the type plate (000000-0000-000000).
DHB-E ...
2
6
_0
2_0
2
_0
8
1
8
Содержание DHB-E 11 SLi electronic
Страница 115: ...www stiebel eltron com DHB E SLi A electronic 115 1 2 f f 1 3 2 2 1 2 2 43 C 2 3 CE CE 3...
Страница 118: ...118 DHB E SLi A electronic www stiebel eltron com 8 1 8 2 8 3 43 C f f f 43 C f f 26_02_02_0833 8 4...
Страница 125: ...www stiebel eltron com DHB E SLi A electronic 125 DHF DHF 180 DHF 26_02_02_0815 10 3 10 180 f f f T f f 26_02_02_0817...
Страница 127: ...www stiebel eltron com DHB E SLi A electronic 127 13 2 3 3 DFE DFE 3 STB 45 C 45 C...
Страница 131: ...www stiebel eltron com DHB E SLi A electronic 131...