iNSTallaTiON
Specification
EN
GL
ISH
www.stiebeleltronamericas.com
DCE Plus|
19
16.7 Data table
DCE 10 Plus
DCE 13 Plus
DCE 15 Plus
238150
238151
238152
Electrical data
Rated voltage
V
208
220
240
208
220
208
220
240
Rated output
1
kW
5.4/7.2
6.0/8.0
7.2/9.6
11.8
13.2
9.0/10.7
10.0/12.0
12.0/14.4
Rated current
A
25.8/34.4
27.3/36.4
30.0/40.0
56.7
60.0
43.3/51.6
45.5/54.5
50.0/60.0
Recommended circuit breaker size
2
A
30/35
30/40
30/40
60
50/60
Min. recommended wire size
3
(AWG copper)
8
6
6
Frequency
Hz
50/60
50/60
50/60
Phase
1/N/GND | 2/GND
1/N/GND | 2/GND
1/N/GND | 2/GND
Resistivity ρ15 ≥
Ω cm
1100
1100
1100
Conductivity
σ
15 ≤
μS/cm
910
910
910
Max. mains impedance at 50 Hz
Ω
0.0407
0.0385
0.0353
0.0248
0.0234
0.0272
0.0257
0.0235
Connections
Water connection
½˝ NPT
½˝ NPT
z˝ NPT
Application limits
Max. permissible pressure
MPa
145 (1)
145 (1)
145 (1)
Max. inlet temperature for reheating
°F (°C)
131 (55)
131 (55)
131 (55)
Temperature setting range
°F (°C)
68–140 (20–60)
68–140 (20–60)
68–140 (20–60)
Values
Max. inlet temperature (e.g. pasteurization)
°F (°C)
158 (70)
158 (70)
158 (70)
Activation rate
gpm (l/min)
0.264 (1.0)
0.264 (1.0)
0.264 (1.0)
Hydraulic data
Nominal capacity
gal (l)
0.07 (0.277)
0.07 (0.277)
0.07 (0.277)
Versions
Adjustable connected load
Yes
No
Yes
Protection class
1
1
1
Insulating block
Plastic
Plastic
Plastic
Heating system
Direct Coil
™
Direct Coil
™
Direct Coil
™
Cover and back panel
Plastic
Plastic
Plastic
Color
White
White
White
IP rating
IP 24
IP 24
IP 24
Dimensions
Height
in (mm)
14
5
/
8
˝ (372)
14
5
/
8
˝ (372)
14
5
/
8
˝ (372)
Width
in (mm)
8
9
/
16
˝ (217)
8
9
/
16
˝ (217)
8
9
/
16
˝ (217)
Depth
in (mm)
4
5
/
16
˝ (109)
4
5
/
16
˝ (109)
4
5
/
16
˝ (109)
Weights
Weight
lb (kg)
5.5 (2.50)
5.5 (2.50)
5.5 (2.50)
1
For units with adjustable power output, factory default setting is jumper position 2 [high]
2
Overcurrent protection sized at 100% of load. Tankless water heaters are considered a non-continuous load. Use only GFCI Class A circuit breakers.
3
Copper conductors with a temperature rating of 75 °C or greater must be used. Conductors should be sized to maintain a voltage drop of less than 3% under
load.
These are our recommendations. Check local codes for compliance if necessary.
Note
The water heater conforms to IEC 61000-3-12.