STIEBEL ELTRON 692500 Скачать руководство пользователя страница 2

2

 | Scale TAC-ler Plus www.stiebel-eltron-usa.com

CONTENTS | SPECIAL INFORMATION 

SPECIAL INFORMATION

OPERATION

1. 

General information _________________________________________2

2. 

Package contents & parts list _______________________________2

2.1 

Key components parts list _____________________________________ 3

3. 

Operating conditions ________________________________________3

INSTALLATION

4. 

General information _________________________________________4

5. 

Required supplies ____________________________________________4

6. 

Installation ____________________________________________________4

6.1 

Select an installation location. ________________________________ 4

6.2 

Shut off main water supply and drain pipes. ______________ 4

6.3 

Cut into existing main water line _____________________________ 4

6.4 

Mount on wall ____________________________________________________ 4

6.5 

Connect to existing plumbing _________________________________ 5

6.6 

Open filter cartridge ____________________________________________ 5

6.7 

Turn on the water ________________________________________________ 5

7. 

After installation _____________________________________________5

7.1 

Water heaters_____________________________________________________ 6

7.2 

Dishwashers ______________________________________________________ 6

7.3 

Glass shower doors _____________________________________________ 6

8. 

Maintenance __________________________________________________6

8.1 

Obtaining replacement filter cartridges _____________________ 6

8.2 

Filter cartridge replacement procedure _____________________ 6

9. 

Data table _____________________________________________________7

10. 

Warranty ______________________________________________________7

OPERATION

1.  General information

Thank you for your purchase of your Scale TAC-ler Plus Series 
Salt-Free Hard Water Conditioner. You have purchased one of the 
finest hard water treatment systems on the market today. Scale 
TAC-ler Plus uses the latest in salt-free hard water conditioning 
media technology to reduce or eliminate hard water mineral scale 
in tankless water heaters. Scale TAC-ler Plus is an environmental-
ly-friendly alternative to conventional water softeners to prevent 
the formation of hard water scale in your plumbing system, water 
treatment equipment, water heater, dishwasher, and more.

This manual is designed to provide owners, installers, and service 
technicians with detailed information about the installation, start-
up, and operation of your new water treatment system. 

The heart of your Scale TAC-ler Plus system is its highly-specialized 
Template Assisted Crystalization (TAC) media. To ensure optimal 
performance and life of your TAC media, it is important that these 
instructions be followed and that the system is operated within the 
technical specifications provided. Your warranty may be voided 
if you fail to follow these instructions and/or fail to operate your 
treatment device within the guidelines noted.

Your Scale TAC-ler Plus water treatment system is designed to offer 
low maintenance operation. The Scale TAC-ler Plus filter cartridge 
will need to be replaced roughly every 2 years. As the TAC media 
is the most critical component to the success of your Scale TAC-ler 
Plus system, we strongly recommend that only authentic Stiebel 
Eltron Scale TAC-ler Plus Series filter cartridges be used to replace 
your cartridges.

NOTE:

 

Read these instructions carefully before using the ap-
pliance and keep them for future reference. 
Pass on the instructions to a new user if required.

2.  Package contents & parts list

The Scale TAC-ler Plus arrives with the following parts included:

 

f

one heavy-duty filter housing with ¾˝ NPT fittings, and pres-
sure relief button

 

f

one mounting bracket and related hardware

 

f

one Scale TAC-ler Plus filter cartridge (shipped inside housing 
- remove protective foam packaging before using)

 

f

one spanner wrench

SPECIAL INFORMATION

Important Notes:

 

- Please read this manual carefully before attempt-

ing installation. Failure to follow these instruc-
tions may void your warranty, cause injury, or 
result in property damage.

 

- The housing sump should be replaced every 10 

years or if you notice any cracks or damage.

 

- This filter system should not be used with water 

that is microbiologically unsafe or of unknown 
quality without adequate disinfection before and/
or after the system. 

 

- Water filter systems should never be exposed to 

freezing temperatures - severe damage to the fil-
ter and housings could result. Such damage is not 
covered under any warranty.

 

- After prolonged periods of non-use (such as a 

vacation), it is recommended that the system be 
flushed thoroughly for at least 5-10 minutes be-
fore using the water.

Содержание 692500

Страница 1: ...ND INSTALLATION UTILISATION ET INSTALLATION Hard Water Mineral Scale Prevention for Tankless Water Heaters Pr vention des d p ts de calcaire dans l eau dure pour les chauffe eau sans r servoir Scale T...

Страница 2: ...our plumbing system water treatment equipment water heater dishwasher and more This manual is designed to provide owners installers and service technicians with detailed information about the installa...

Страница 3: ...ated levels of chlorine iron manganese hydrogen sulfide copper and cer tain other contaminants can damage the TAC media reducing its effectiveness and shortening its life Water exceeding any of the fo...

Страница 4: ...nt equipment if you are using this product to treat all of the water for the building is as follows Pressure Tank or Water Meter If Applicable Branch Line to Outdoor Irrigation Backwashing Iron Filter...

Страница 5: ...pressure will at any time exceed the maximum rating of 90 psi 6 2 Bar a pressure regulator must be installed before the sys tem It is recommended that the pressure regulator be set at 75 psi 5 2 Bar o...

Страница 6: ...allows the majority of the nano particles to be easily washed to drain The few nano particles that are left can be easily wiped down because they can no longer adhere to the sides of the shower 8 Main...

Страница 7: ...ns Housing material Polypropylene Pressure drop 1 psi at 6 gpm 0 1 bar at 22 7 l min Max treatment service flow rate 6 gpm 22 7 l min Max flow rate through device 10 gpm 37 85 l min Max pressure 90 ps...

Страница 8: ...l warranties on behalf of Stiebel Eltron Inc and no statement warranty or guarantee made by any other party shall be binding on Stiebel Eltron Inc Stiebel Eltron Inc shall not be liable for any damage...

Страница 9: ...de l eau Le c ur de votre syst me TAC ler Scale est son support hautement sp cialis pour la cristallisation assist e par matrice TAC Pour assurer des performances et une dur e de vie optimales de vot...

Страница 10: ...ce de niveaux lev s de chlore de fer de mangan se de sulfure d hydrog ne de cuivre et de certains autres contaminants peut endommager le TAC r duire son ef cacit et raccourcir sa dur e de vie Les eaux...

Страница 11: ...au entrant dans le b timent ce ltre doit tre install sur la canalisation d eau froide principale apr s le r servoir sous pression ou le compteur d eau et apr s la plupart des quipements de traitement...

Страница 12: ...ivre nouvellement install s avant l unit Scale TAC ler Plus il est recommand de diff rer l ins tallation de la cartouche Scale TAC ler Plus de 3 4 se maines afin de permettre la formation d un rev tem...

Страница 13: ...le Pour acc l rer le d tartrage dans votre lave vaisselle vous pou vez mettre une tasse de vinaigre blanc dans le panier sup rieur pendant le cycle de lavage des premi res semaines Vous pouvez galemen...

Страница 14: ...de logement sur le bou chon du logement Serrez la main seulement Il n est pas n cessaire de trop serrer pour cr er une bonne tanch it Vous pouvez utiliser la cl molette pour une prise en main confort...

Страница 15: ...t autoris donner toutes les garanties au nom de Stiebel Eltron Inc et aucune d claration garantie ou garantie faite par une autre partie ne liera Stiebel Eltron Inc Stiebel Eltron Inc ne sera pas resp...

Страница 16: ...1036 Budapest Tel 01 250 6055 Fax 01 368 8097 info stiebel eltron hu www stiebel eltron hu Japan NIHON STIEBEL Co Ltd Ebara building 3F 2 9 3 Hamamatsu cho Minato Ku 105 0013 Tokyo Tel 03 34364662 Fa...

Отзывы: