INSTALLATIoN
Specification
24
| CNS TREND | CNS TREND U www.stiebel-eltron.com
14. Specification
14.1 Dimensions and connections
b01
a20
450
100
256
i13
D
00000
68
09
5
CNS 50
TREND (U)
CNS 75
TREND (U)
CNS 100
TREND (U)
CNS 150
TREND (U)
CNS 200
TREND (U)
CNS 250
TREND (U)
CNS 300
TREND (U)
a20 Appliance
Width
mm
348
426
426
582
738
894
1050
i13 Wall mounting bracket
Horizontal
hole spacing
mm
101
179
179
335
491
647
803
b01 Entry electrical cables
14.2 Energy consumption data
The product data complies with EU regulations relating to the
Directive on the ecodesign of energy related products (ErP).
CNS 50 … CNS 75 … CNS 100 … CNS 150 … CNS 200 … CNS 250 … CNS 300 …
… TREND
… TREND U
236524
236545
236525
236546
236526
236547
236527
236548
236528
236549
236529
236550
236530
236551
Manufacturer
STIEBEL
ELTRON
STIEBEL
ELTRON
STIEBEL
ELTRON
STIEBEL
ELTRON
STIEBEL
ELTRON
STIEBEL
ELTRON
STIEBEL
ELTRON
Heating output
Rated heating output P
nom
kW
0.5
0.75
1.0
1.5
2.0
2.5
3.0
Minimum heating output (standard value) P
min
kW
0.5
0.75
1.0
1.5
2.0
2.5
3.0
Maximum continuous heating output P
max,c
kW
0.5
0.75
1.0
1.5
2.0
2.5
3.0
Auxiliary power consumption
At rated heating output el
max
kW
0.000
0.000
0.000
0.000
0.000
0.000
0.000
At minimum heating output el
min
kW
0.000
0.000
0.000
0.000
0.000
0.000
0.000
In standby el
SB
kW
0.000
0.000
0.000
0.000
0.000
0.000
0.000
Type of heating output/room temperature control
Single stage heating output, no room temperature control
-
-
-
-
-
-
-
Two or more manually selectable stages, no room temperature
control
-
-
-
-
-
-
-
Room temperature control with mechanical thermostat
-
-
-
-
-
-
-
With electronic room temperature control
-
-
-
-
-
-
-
Electronic room temperature control and time of day control
-
-
-
-
-
-
-
Electronic room temperature control and day of week control
x
x
x
x
x
x
x
Other control options
Room temperature control with presence detection
-
-
-
-
-
-
-
Room temperature control with window open detection
x
x
x
x
x
x
x
With remote control option
-
-
-
-
-
-
-
With adaptive control of heating start
x
x
x
x
x
x
x
With operating time limitation
-
-
-
-
-
-
-
With black bulb sensor
-
-
-
-
-
-
-