17 West St., W. Hatfi eld, MA 01088
|
800.582.8423
|
413.247.3380
|
fax 413.247.3369
|
|
www.stiebel-eltron-usa.com
Simply the Best
INSTALLATION INSTRUCTIONS
SOL 27 PREMIUM S & W COLLECTORS - 230016 & 230017
single pane safety glass. As the light strikes the absorber
plate, it is converted to heat. The highly selective vacuum
coating of the absorber and the thermal insulation on the
back of the absorber keep heat lossed to the environment to
a minimum.
The thermal energy produced by the collector is transported
by the heat transfer medium (solar loop fl uid), via a
circulating pump, to the storage tank(s)/ The inside of the
collector can fog up under certain operating conditions
(e.g., large tank with low temperature compared to the
outdoor temperature and/or high relative humidity). Vent
holes are provided in the collectors for venting humidity and
equalizing air pressure.
Technical Data & Specifi cations
Type
SOL 27 Premium S SOL 27 Premium W
Item Number
230016
230017
Type
Standard / Vertical
Wide / Horizontal
Height
85.5˝ / 2171 mm
46.1˝ / 1171 mm
Width
46.1˝ / 1171 mm
85.5˝ / 2171 mm
Depth
3.8˝ / 96 mm
3.8˝ / 96 mm
Weight
88.2 lb / 40 kg
89.3 lb / 40.5 kg
Casing material
Aluminum, corrosion resistant
Glass cover
ESG
Glass thickness
0.125˝ / 3.2 mm
Thermal insulation thickness
2˝ / 50 mm
Thermal insulation material
Mineral wool, low outgassing, WLG 040
Collector connection
22 mm plug-in connector
Max. idle temperature
<410
F / 210
C
Min. operating pressure
50.75 psi / 0.35 MPa
Max. permissible pressure
87 psi / 0.6 MPa
Pressure drop @ 1 gpm
0.75 ft. head
Test pressure
247 psi / 1.7 MPa
Test medium
40% Propylene Glycol
Fluid capacity
0.4 gal / 1.5 l
0.48 gal / 1.83 l
Nominal fl ow rate
0.25 - 3.75 gpm
Angle of inclination
10 - 90
Total area
27.34 ft² / 2.54 m²
Aperture area
25.73 ft² / 2.39 m²
Absorber area
25.62 ft² / 2.38 m²
Absorber material
Aluminum, highly selective coating,
copper pipes, laser welded
Gasket
EPDM
Conversion factor
η
0
0.82
0.83
Effective heat transfer coef. a1
3.46 W / (m
²
K)
Effective heat transfer coef. a2
0.0153 W / m
²
K
²
Absorption level
α
95% ± 2%
Emission level
ε
5% ± 1%
Collector yield
>525 kWh / (m
²
) per year
2 5
3
3.5
4
4.5
p
(f
t. head)
SOL 27 Premium S & W Pressure Drop Curves
0
0.5
1
1.5
2
2.5
0
0.5
1
1.5
2
2.5
3
Pr
essu
re
Dr
o
p
Flow Rate (GPM)
SOL 27 Premium S
SOL 27 Premium W