background image

 

For professional use only 

INSTALLATION 
MANUAL OF DOUBLE 
GLASS MODULE

 

Содержание CS6R-MB-AG

Страница 1: ...For professional use only INSTALLATION MANUAL OF DOUBLE GLASS MODULE...

Страница 2: ...0 MODULE INSTALLATION 6 5 1 MODULE WIRING 9 5 2 GROUNDING 12 6 0 MOUNTING INSTRUCTIONS 13 6 1 MOUNTING METHODS BOLTING 14 6 2 MOUNTING METHODS CLAMPING 16 6 3 INSERTION SYSTEMS 20 6 4 MOUNTING METHOD...

Страница 3: ...ATION OF LIABILITY Canadian Solar shall not be held responsible for damages of any kind including without limitation bodily harm injury or damage to property in connection with handling PV modules sys...

Страница 4: ...each module label Please refer to the datasheet or the product nameplate for the maximum system voltage Under certain conditions a module may produce more current or voltage than its Standard Test Con...

Страница 5: ...ng exposed to moisture or sunlight like using connector endcaps Protect the package from damage In any circumstances pallets with landscape oriented module packaging shall not be stacked vertically mo...

Страница 6: ...n modules under any circumstances Localized heavy loads may cause severe micro cracks at cell level which in turn may compromise module reliability and void Canadian Solar s warranty Do not change the...

Страница 7: ...DITIONS PV modules are intended for use in general open air climates as defined in IEC 60721 2 1 Classification of environmental conditions Part 2 1 Environmental conditions appearing in nature Temper...

Страница 8: ...umstances Only modules with similar electrical parameters should be connected in the same string to avoid or minimize mismatch effects in arrays To minimize risk in the event of an indirect lightning...

Страница 9: ...back of the module This also allows condensation or moisture to dissipate According to UL 61730 any other specific clearance required for maintaining a system fire rating should prevail Detailed clear...

Страница 10: ...tallation Portrait installation one row CS3W Cable length per lead 400 mm 280 mm CS3Y CS6W Cable length per lead 410 mm 290 mm CS7L CS7N Cable length per lead 460 mm 340 mm CS6R CS6RA Cable length per...

Страница 11: ...stallation one row Leap frog for single axis tracker CS3W CS3Y Cable length 1850 mm 1850 mm CS6W Cable length 2000 mm 2000 mm The maximum distance between two adjacent module frames should be within 5...

Страница 12: ...city complies with local regulations i e NEC 690 8 D CABLE AND CONNECTOR PROTECTION Secure the cables to the mounting system using UV resistant cable ties Protect exposed cables from damage by taking...

Страница 13: ...onal engineer The mounting design and procedures must comply with all applicable local codes and requirements from all relevant authorities The system designer and installer are responsible for load c...

Страница 14: ...X 1 25 Grade 8 8 5 16 18 Grade B7 galvanized or A2 70 stainless steel bolt and nut should be used Plain washer size should be M8 with outer diameter 16 mm The yield strength of bolt and nut should no...

Страница 15: ...er four holes installation method A Inner four holes installation method B Middle four holes installation method A Middle four holes installation method B Outer four holes installation method A Outer...

Страница 16: ...mounting rails shall be designed to limit as much as possible shade on module rear side cells Canadian Solar s warranty may be void in the cases where improper clamps or unsuitable installation metho...

Страница 17: ...G CS3W PB AG 410 490 CS3Y MB AG CS3Y PB AG 300 600 400 550 CS6R H AG 400 550 450 500 CS6RA H AG 300 450 350 400 CS6W MB AG 300 600 400 500 CS7N MB AG CS7L MB AG 400 500 CS6R MB AG 300 600 400 500 6 2...

Страница 18: ...Pa 3600 2400 4000 3200 4400 3200 4400 3600 A1 Range mm CS3W MB AG CS3W PB AG 410 490 CS3Y MB AG CS3Y PB AG 400 550 CS6W MB AG 400 500 CS6RA H AG 300 400 CS7N MB AG CS7L MB AG CS6R H AG 400 500 CS6R MB...

Страница 19: ...2022 CSI Solar Co Ltd www csisolar com 6 2 5 Six clamps on long side of frame and rails perpendicularly to the long side frame Module Types Max Mechanical Load Pa 6000 3600 A3 A5 Range mm CS6RA H AG...

Страница 20: ...gn of support structure Canadian Solar warranty may be void in cases where improper insertion systems or unsuitable installation methods are found When installing insertion profiles please take the fo...

Страница 21: ...g for advice Tracker 1P Bolting method Install and tighten the module clamps to the mounting rails using the torque stated by the mounting hardware manufacturer M6 X 1 1 4 or M8 X 1 25 5 16 bolt and n...

Страница 22: ...er 2P Bolting method Module type Mounting hole space mm Mounting hole location Plain washer outer diameter mm Test load Pa CS3W PB AG CS3W MB AG A1 A3 400 B1 B3 1155 B1 B2 A3 A4 16 1800 1600 B1 B2 B3...

Страница 23: ...ng the potential electric shock hazard Cracked or broken modules represent an electric shock hazard due to leakage currents and the risk of shock is increased when modules are wet Before cleaning thor...

Страница 24: ...ar recommends cleaning the soft dirt like dust on modules just with air pressure This technique can be applied as long as the method is efficient enough considering the existing conditions Method B We...

Страница 25: ...0PB AG 410 39 1 10 49 47 6 11 06 25 CS3W 415PB AG 415 39 3 10 56 47 8 11 14 25 CS3W 420PB AG 420 39 5 10 64 48 0 11 26 25 CS3W 425PB AG 425 39 7 10 71 48 2 11 29 25 CS3W 430PB AG 430 39 9 10 78 48 4 1...

Страница 26: ...12 43 31 2 13 28 25 CS6RA 330H AG 330 26 5 12 53 31 2 13 33 25 CS6RA 335H AG 335 26 6 12 63 31 2 13 38 25 CS6RA 340H AG 340 26 8 12 73 31 3 13 43 25 CS6RA 345H AG 345 26 9 12 83 31 3 13 48 25 CS6R 415...

Страница 27: ...9 16 97 40 3 18 22 35 CS7L 580MB AG 580 34 1 17 02 40 5 18 27 35 CS7L 585MB AG 585 34 3 17 06 40 7 18 32 35 CS7L 590MB AG 590 34 5 17 11 40 9 18 37 35 CS7L 595MB AG 595 34 7 17 15 41 1 18 42 35 CS7L 6...

Страница 28: ...ceeded 175 2 hours The operational module temperature is influenced by the environmental temperature but also by how the module is installed e g mounting distance to rooftop array size array spacing a...

Страница 29: ...rtment or our local representatives for more information The reliability of photovoltaic modules strongly depends on their distance from the coastline Different coastal land areas are defined accordin...

Страница 30: ...trochemical potentials of two different coating materials If mounting components consist of two metals with a big difference in electrochemical potential please add insulating washers e g bi metallic...

Страница 31: ...f the mounting system is not provided by Canadian Solar The requirements below apply to two main mounting systems aluminum alloy based racking for rooftops and galvanized steel based structures for gr...

Страница 32: ...allation and inspection requirements When applying coating materials workers must follow applicable health and safety legislation and apply all respective preventive and proactive measures described w...

Страница 33: ...is released in April 2020 Rev 1 6 is released in May 2020 Rev 1 7 is released in December 2020 Rev 1 71 is released in December 2020 Rev 1 8 is released in March 2021 Rev 1 9 is released in June 2021...

Отзывы: