![STIEBEL ELTRON 200254 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/stiebel-eltron/200254/200254_operation-and-installation_1376771009.webp)
iNSTallaTiON
appliance description
EN
GL
ISH
www.stiebel-eltron.com
CWM P | CWM U |
9
9. Appliance description
9.1 Standard delivery
The following are delivered with the appliance:
- Wall mounting bracket (hooked into the appliance)
10. Installation
10.1 Installation site
Installation in bathrooms
WARNING Electrocution
When installing the appliance in rooms with a bath and/
or shower, the appliance may only be connected to a
standard socket outside safety zones 0, 1 and 2. The
socket must be at least 600 mm away from a bath or
shower. If in doubt, consult a qualified contractor.
600
600
2250
1
2
3
0
D
00000
97
13
7
Electrical safety zones in the bathroom
10.2 Minimum clearances
≥150
≥100
≥100
≥100
≥500
≥
20
D
00000
68
09
6
10.3 Installing the wall mounting bracket
The appliance is intended for wall mounting using the wall mount-
ing bracket supplied. The appliance may only be installed hori-
zontally.
Note
- The wall mounting bracket can be used as a tem-
plate for wall mounting. This ensures sufficient
clearance from the floor.
- Use a spirit level if the floor is uneven or sloping.
aaa
D
00000
72
15
9
1
3
2
4
≥224
≥224
D
00000
72
31
2
f
Unhook the wall mounting bracket from the appliance.
f
Place the centred wall mounting bracket horizontally on the
floor. Mark holes 1 and 2.
f
Lift up the wall mounting bracket so that its lower holes
match up with the markings you have just made on the in-
stallation wall.
f
Mark holes 3 and 4 on the installation wall.
f
Drill the holes at the 4 markings.
f
Secure the wall mounting bracket with suitable fixing ma-
terials (screws, rawl plugs). With the vertical slots, you can
compensate for an offset fixing hole.