STEP 1 - MOUNTING OPTIONS
4
INSTALLATION OF ALARM
O
DRILL
3-/16 DIA HOLES
19018 ANCHOR
#8-10
(2) PROVIDED
19039 SCREW
#6 x 1 1/4 in.
(2) PROVIDED
BASE PLATE
18074 SWITCH LOCK
SUB-SA505 KEY SWITCH
MOUNTING BRACKET
3 9/32 in.
18075 REPLACEMENT
#801 KEY
O
T
O
K
EY
M
OUNT
P
LATE OR INTO
W
ALL WITHOUT
E
LECTRICAL
B
OX
ENCLOSURE
ROUTE THE TWO KEY
SWITCH WIRES THROUGH
THE HOLE AS SHOWN
WIRE ACCESS HOLE
ROUTE THE TWO REED
SWITCH WIRES FROM
CABINET THROUGH THE
HOLE AS SHOWN
E
INSTALLATION OF CABINET
1. Insert the (4) 06298
mounting tabs fully into
backbox mounting tab
slots. Use rubber mallet if
necessary.
2. After selecting a suitable
location, place cabinet in
closed position, against the wall. Mark and drill (4) 1/4 in. diameter holes.
Insert the (4) 19033 anchors. Mount cabinet by driving in the four #10 x
1 1/2 in. screws.
3. For STI-7531AED select one of the two shelf mounting locations, install
shelf. Close and lock cabinet.
backbox mounting tab slot
mall
in closed position, against the wa
drill (4) 1/4 in. diamet
19033 anchors.
3
install shelf. Nex
through the acc
view A. Close and lock cabinet
wire
Drive in the (4) scre
of cabinet
optional mounting holes
diamet
mounting plat
drive the (2) alarm mounting scre
pre
the terminal switch diagram shown in view B.
4
scre
M
19033 ANCHOR
(4) PROVIDED
04875 MOUNTING PLATE
PROVIDED
19002 SCREW
#8-32 x 3/8 in.
(4) PROVIDED
OPTIONAL SHELF
MOUNTING POSITION
07530WR
ADJUSTABLE SHELF
INCLUDED WITH
STI-7531AED ONLY
07530 CABINET
ASSEMBLY
6297530
GASKET PROVIDED
06298
MOUNTING TABS (4) PROVIDED
19013 SCREW
#10 x 1 1/2 in.
(4) PROVIDED
MOUNTING
TAB SLOTS
STI-7530 KEYLOCK
STI-7531 AND
STI-7531AED THUMBLOCK
Note:
Installation of cabinet
should be before
installation of alarm
because the mounting
bracket butts up to
cabinet.