background image

— 1 —

Installation and Operation Manual

STI Universal Sensor

Thank you for purchasing the STI Universal Sensor. Your satisfaction is very important to us. Please take 
the time to read this manual carefully to get the most from your new product.

How The Product Works

The STI Universal Sensor is a wireless transmitter that can be configured to initiate a transmission to any 
STI Receiver three different ways: internal magnetic sensor, internal tilt sensor or external switch.

Plan Your Installation

1)  Refer to the 

Operation

 section on the following pages to determine which sensor configuration is 

best for your application.

2)  Refer to the 

Sensor Supervision

 section to understand the use of this feature. It is recommended 

to leave the sensor in the supervised state (J3 uncut) until false trouble signals are displayed on the 
receiver. If you need to disable sensor supervision, the sensor must be deleted from the receiver 
and reprogrammed into the receiver. Refer to your 

receiver’s installation instructions

.

Model:

     

STI-34401

Jumper Configurations

APPROXIMATE GAP (1 INCH) 
GAP MAY BE EFFECTED
IF MOUNTED ON METAL.

“RESTORE”

CLOSED

“ALERT”

CLOSED

“ALERT”

OPENED

APPROXIMATE GAP (1 INCH) 
GAP MAY BE EFFECTED
IF MOUNTED ON METAL.

MAGNETIC SENSOR CABLE
(18 INCHES)

APPROXIMATE GAP
(GREATER THAN 1 1/3 INCHES)
GAP MAY BE EFFECTED
IF MOUNTED ON METAL.

“ALERT”

“RESTORE”

“ALERT”

OPENED

APPROXIMATE GAP
(GREATER THAN 1 1/3 INCHES)
GAP MAY BE EFFECTED
IF MOUNTED ON METAL.

VINYL ELECTRICAL
TAPE

19039 SCREW
(2) PROVIDED

KNOCK OUT FOR WIRES

OF EXTERNAL SWITCH

J3

J1 J2

“RESTORE”

CLOSED

“ALERT”

OPEN

MAGNETIC SENSOR

“ALERT”

“RESTORE”

TILT SENSOR

EXTERNAL TERMINALS

“RESTORE”

CLOSED

“ALERT”

OPEN

EXTERNAL SWITCH
CONNECTION BLOCK

ONBOARD
MAGNETIC SENSOR

MAGNET LOCATION 
FOR MAGNETIC SENSOR

EXTERNAL SWITCH
CONNECTION BLOCK

TAMPER SWITCH

ONBOARD
MAGNETIC SENSOR

OPTION 1 MOUNTING

(DOUBLE SIDED FOAM TAPE)

OPTION 2 MOUNTING

VINYL ELECTRICAL
TAPE

19039 SCREW
(2) PROVIDED

KNOCK OUT FOR WIRES

OF EXTERNAL SWITCH

EXTERNAL SWITCH
CONNECTION BLOCK

TAMPER SWITCH

ONBOARD
REED SWITCH

Fig. 1

1. Open sensor case using a flat head screwdriver in side case slot.
2. Configure the jumpers for the desired application (see Jumper Configurations Fig. 1).
3. Activate battery by removing the red tape.
4. Program the STI Universal Sensor into the STI receiver. Refer to the STI 

receiver installation 

instructions

 for programming instructions.

5. Snap base into lid. Tamper switch spring automatically seats within the locator ring on the lid.  Tamper 

alert is triggered when the spring releases identifying when case is opened/broken/ajar.

6. Test the sensor for proper operation before permanently mounting.
7. Select mounting option.

OPTION 1:  Mount with double sided foam tape provided to the back of the case (Fig. 2).
OPTION 2:  Remove the circuit board from the case bottom.  Drill 1/8 inch holes through the case 
and use the screws (provided).  For added protection, cover metal screw heads on the inside of 
the case bottom with electrical tape (Fig. 2) to isolate the circuit board.  Replace the circuit board 
in the case bottom.

Universal Sensor Setup

*Magnetic Sensor (supervised)
Tilt Sensor (supervised)
External Terminals (supervised) N.O.
External Terminals (supervised) N.C.
Magnetic Sensor (not supervised)
Tilt Sensor (not supervised)
External Terminals (not supervised) N.O.
External Terminals (not supervised) N.C.

J1 J3 J2

  
X
X  X
   X
 X
X X
X X X

 

X X

NOTE:

 After cutting jumpers, tape each of the cut ends with 

electrical tape to prevent wires from shorting.

*Factory Setting

Cut jumpers with “X”, do not cut jumpers with “   ”.

Содержание STI-34401

Страница 1: ...ETIC SENSOR MAGNET LOCATION FOR MAGNETIC SENSOR Fig 1 1 Open sensor case using a flat head screwdriver in side case slot 2 Configure the jumpers for the desired application see Jumper Configurations Fig 1 3 Activate battery by removing the red tape 4 Program the STI Universal Sensor into the STI receiver Refer to the STI receiver installation instructions for programming instructions 5 Snap base i...

Страница 2: ...AGNETIC SENSOR CABLE 18 INCHES APPROXIMATE GAP GREATER THAN 1 1 3 INCHES GAP MAY BE EFFECTED IF MOUNTED ON METAL ALERT OPENED APPROXIMATE GAP GREATER THAN 1 1 3 INCHES GAP MAY BE EFFECTED IF MOUNTED ON METAL APPROXIMATE GAP 1 INCH GAP MAY BE EFFECTED IF MOUNTED ON METAL RESTORE CLOSED ALERT CLOSED ALERT OPENED APPROXIMATE GAP 1 INCH GAP MAY BE EFFECTED IF MOUNTED ON METAL MAGNETIC SENSOR CABLE 18 ...

Страница 3: ...on can be disabled for installations where the transmission signals may be locked when in the sensor s normal condition not supervised If the STI Universal Sensor has a Low Battery or triggered Tamper Switch the sensor will send a trouble signal to the receiver If the signal is out of range or there is a loss of communication the receiver will indicate a trouble condition between 12 and 24 hours f...

Страница 4: ... and office use in all EU and EFTA member states Additional Wireless Alert Series Products STI 34098 Single Channel Slave Receiver STI V34104 4 Channel Voice Receiver STI 34108 8 Channel Receiver STI 34188 8 Zone Relay Board STI 34101 Solar Powered Driveway Monitor Sensor STI 34151 Battery Powered Driveway Monitor Sensor STI 34201 Wireless Mail Alert Sensor STI 34301 Wireless Garage Sentry Sensor ...

Отзывы: