14
Assembly roof-tile clamps
with lead
Completely tiled roof.
Removal of the tiles after previous determination of the placement
of the roof-tile clamps (see page 10 „Spacing multi-row collector
fields“)
When mounting the field in regions with snow load zone III and
higher or with expected increased snow loads, it is necessary to
place the roof hooks in the rafter area.
Completely lifted area for placement of a hook.
Mount the lower lath 24x80x600 mm with two screws 4x50 mm.
If the lath is placed near the counter lath, the lath 24x80x600 mm
must not be applied.
1410002 Roof-tile clamp V2 with lead
Replace the lower roof-tile.
Afterwards the tile clamp support 24x150x270 mm is to be fixed with
two screws 6x60 mm.