28
The
TXM
control has a lock to prevent the control keys from being accidently
pushed. Follow these steps to lock and unlock the keys of your control:
1. Press the
POWER
button. The control’s transmission LED will remain on.
2. Press the SOURCE and MUTE keys at the same time. The transmission
LED on the control will blink 2 times indicating that the control is locked or it will
blink 5 times indicating that the control has been unlocked.
The
STM 1003
and its
TXM
control are
SYNCHRONIZED
at the factory. If the owner
purchases new
TXM
controls to use with the
STM 1003
, whether to replace the
current control or to have more than one control, follow these steps:
To synchronize more than one control
(maximum 8)
, repeat steps
1
to
3
. If more
than 8 controls are synchronized, the newest control will override the oldest
control.
1.
Press the
SYNC/RST
key on the rear panel
of the
STM 1003
. The sound mixer’s LED
will blink for 15 seconds.
2.
Press one of the
TXM
control’s keys
(except the POWER key)
3.
The LED of the
STM 1003
wil stop blinking.
Sync is complete.
Lock/Unlock Keys
Synchronization of the STM 1003
SYNC/RST
Key
Press one of the
keys.
LED
Indicator
Note:
Before beginning the synchronization, make sure there are no
other
TXM
controls operating within the range of the
STM 1003
as
they could interfere.