10
11
remote coNtroL FUNctioNS - Soap & Water
remote coNtroL FUNctioNS - Soap & Water
Adjusting the settings with the remote control
If necessary, the sensor settings can be adjusted as following:
Shut off the water supply. In order to adjust the sensor with the remote control, hold
the remote control straight in front of the sensor in a distance of about 6-8” (15-20cm).
Choose the function you want to adjust by pressing once on one of the function buttons.
After pressing once on a specific function button, a quick flashing of the LED in the
front of the sensor will occur. At this stage, you can change the setting by pressing the
(+) or the (-) buttons, every push will increase or decrease one level. After finishing the
adjustment, turn the water supply back on.
DETECTION RANGE:
The detection range refers to the greatest distance an object can be
located to activate the system.
The sensor range can be changed using this button on the remote
control.
Press the Range button. Wait until a quick flashing of the LED in the
sensor eye is perceived. Then, press + to increase the detection range
and – to reduce it.
Note: Once you have changed the detection range with the remote control, the
distance will be remembered by the sensor, even if the power source is disconnected.
To get back to the self adjustment mode, use the ADJ button only.
ENTRANCE TO THE SELF ADJUSTmENT mODE:
This button operates faucets including a self adjusting sensor only.
Check that no objects are in front of the sensor. Press the ADJ button.
Once a quick flashing of the LED in the sensor eye is perceived, remove
your hand holding the remote control away from the sensor area. The
ideal sensor range for the specific location will be set automatically.
Once the self adjustment has taken place the solenoid valve will be
opened and closed for 1 second as an indication that the ideal sensor
range was set and the product is ready for use.
RESET BUTTON:
This function allows the sensor to return to the original factory preset
settings.
If your product includes a self adjusting sensor, the RESET button
restores all the factory settings except for the sensor range. To enter
the self adjusting mode, use the ADJ button. To change the sensor
range, use the RANGE button. If required, press the Reset button and
the + button together.
detectIon
RANGE
soaP
quantIty
FILL THE
tank
TEmPORARY OFF
FUNCTION
ENTRANCE TO THE SELF
ADJUSTmENT mODE
RESET
AIR
quantIty
1-4 DROP
keys
Stern’s advanced
13
keys remote control enables adjustments of products including
a self-adjusting or dual flush sensor. The following settings can be adjusted and the
following functions can be performed: