Stern SWAR Скачать руководство пользователя страница 5

6

7

Step 4 – poWeriNG tHe SyStem

 Important Note:

 The SWAR’s sensors 

are self-adjusting; therefore, the ideal 

sensor range for a given location will be set 

automatically.

Before proceeding, check that there are no 

foreign objects in front of the sensors withing 

300

 mm.

OBJECT

OBJECT

1

Remove the protective stickers that 

cover the sensors, both on the Faucet 

and on the Soap Dispenser.
Re-open the water shut-off valves.

2

To power the faucet and the soap

dispenser, run the end of the

transformer cord through hole B3

then connect it to the power splitter. 

Plug the transformer into the main 

power line.

B3

3

Wait about 

10

 seconds for the Faucet 

and the Soap Dispenser sensors to 

complete their self-adjustment.

10

SECONDS

ABOUT

4

Put your hands under the Faucet and 

the Soap Dispenser and verify their 

functionality.

iNStaLLatioN

FiLLiNG tHe Soap taNk

Step 5– FiLLiNG tHe Soap taNk

1

Unscrew the cover of the soap bottle 

and fill with liquid soap.

2

Place the cover back and screw it 

closed, making sure the hose extends 

to the bottom of the soap bottle.

3

Press the refill button located on the top 

of the pump assembly until soap starts 

coming out of the soap dispenser spout.

This operation can also be done using 

the soap dispenser remote control Refill 

function.

Содержание SWAR

Страница 1: ...1 Installation and maintenance guide Soap Water Air REVOLUTION...

Страница 2: ...formation in this document is provided as is without warranty of any kind either expressed or implied including but not limited to any implied warranties of merchantability fitness for a particular pu...

Страница 3: ...se a pressure reducing valve Sensor range faucet Self adjusting sensor Adjustable with remote control Min 80mm Max 300mm Sensor range soap dispenser Factory Set 150mm adjustable by remote control 30 1...

Страница 4: ...Firmly attach the wall support to the wall Note Ensure the wall support is installed leveled Screws not uncluded 2 Place the SWAR unit on the support Make sure to pass the electrical wire s and valves...

Страница 5: ...o the power splitter Plug the transformer into the main power line B3 3 Wait about 10 seconds for the Faucet and the Soap Dispenser sensors to complete their self adjustment 10 SECONDS ABOUT 4 Put you...

Страница 6: ...diaphragm from the solenoid valve and examine it for dirt In case it is dirty or clogged wash it under running water and reassemble it Do not attempt to dismantle the solenoid valve if you are unfamil...

Страница 7: ...even if the power source is disconnected To get back to the self adjustment mode use the ADJ button only Entrance to the self adjustment mode This button operates faucets including a self adjusting s...

Страница 8: ...al to perform any kind of activity in front of the sensor without operating the system for example cleaning Faucets and or soap dispensers will remain shut for 1 minute when this button is pressed onc...

Страница 9: ...am dispenser components including pipes Troubleshooting faucet PROBLEM INDICATOR CAUSE SOLUTION No water coming out of the faucet LED in the sensor does not flash once when user s hands are within the...

Страница 10: ...onnectors properly so that the white o ring is not visible PROBLEM Corrective actions If the dryer will not run HAZARD BE SURE TO TAKE SUITABLE PRECAUTIONS TO AVOID SHOCK First ensure that the breaker...

Страница 11: ...18 06 18 01500371 A 777 Passaic Avenue Clifton NJ 07012 USA Tel 1 973 773 8011 Fax 1 973 779 8768 Toll Free 1 800 4364410 info sternfaucets com tech sternfaucets com...

Отзывы: