10
11
ENGLISH
ENGLISH
2. Remove the dirty filters and replace with new ones.
3. Secure the cover back onto the turbine.
Never operate your unit without the air filters. Dirt couldbe sucked in and interfere with the
function of the unit.
Troubleshooting
Problem
Cause
Solution
A. Little or no mate-
rial flow
1. Nozzle clogged.
1. Clean.
2. Suction tube clogged.
2. Clean.
3. Material volume setting turned too low(-). 3. Increase volume setting (+).
4. Suction tube loose.
4. Insert.
5. No pressure build up in container.
5. Tighten container.
6. Air filter clogged.
6. Change.
B. Material leaking
1. Nozzle loose.
1. Tighten.
2. Nozzle worn.
2. Replace.
3. Nozzle seal worn.
3. Replace.
4. Material build-up on air cap and nozzle
4. Clean.
C. Atomization is too
coarse
1. Viscosity of material too high.
1. Thin.
2. Material volume too large.
2. Decrease volume setting (-).
3. Material volume setting too high (+).
3. Decrease volume setting (-).
4. Nozzle clogged.
4. Clean.
5. Air filter clogged.
5. Change.
6. Too little pressure build-up in container. 6. Tighten container.
D. Spray jet pulsates 1. Material in container running out.
1. Refill.
2. Air filter clogged.
2. Change.
E.Pattern runs or
sags
1. Applying too much material.
1. Adjust material flow or incre-
ase
movement of spray gun.
F. Too much over-
spray
1. Gun too far from spray object.
1. Reduce distance.
2. Too much material applied.
2. Decrease volume setting (-).
G. Pattern is very
light and splotchy.
1. Moving the spray gun too fast
1. Adjust material flow or
decrease
movement of spray gun.
Parts list
Number
Part Description
Quantity
1
Sprayer Assembly
1
2
Container Seal
1
3
Suction Tube 1
1
4
Seal Ring
1
5
Suction Tube 2
1
6
Container
1
7
Viscosity Cup
1
8
Air Filter
1
9
Air Compressor Assembly
1