PARTS REFERENCE
67
GODZILLA LE / PREMIUM MANUAL 500-55T6-01
PART 2: SOFTWARE LEVELING
1. Power on the game. Proceed to the BUILDING STEPPER MOTOR TEST Menu by
entering the Service Menu -> DIAG -> GAME -> BUILDING STEPPER MOTOR TEST.
COLLAPSING BUILDING ADJUSTMENT PROCEDURE CONTINUED
2. The BUILDING STEPPER MOTOR TEST has two modes, MOVE and ADJUST. The
test menu can be toggled between these two modes by pressing START on the
game cabinet.
a. MOVE Mode: + and – service buttons will cycle through the four floor heights of
the building. Current step position will be reported in the top right corner of the
test menu. Pressing SELECT on the service menu buttons will begin a motor
homing sequence and return the mechanism to the Floor 1 position.
b. ADJUST Mode: + and – service buttons will add or subtract 10 steps to the
Floor 1 position bias. Alter this number until the front edge of the building is in
the preferred Floor 1 position. Ideal Floor 1 position is flush with the top playfield
surface. Pressing the BACK service button will save this adjustment to the cabinet
CPU board.