R a
n g e a d j u s t m e n t
8
5. When the sensor enters into adjusting mode and your hand is in front of the sensor, a slow
flashing of the red light at the front of the sensor will occur.
6. Keep your hand in front of the sensor until the slow flashing changes into quick flashing.
At this point move your hand
to the required distance from the sensor
and wait until the red light will stop flashing.
7. When the red light has
turned off, your sensor has
been adjusted to the
required distance.
8. Check the distance you
have set and if it is not
satisfactory, repeat steps 1-6.
Adjusting the sensor with a remote control - optional:
In order to adjust the sensor with a remote control you hold the remote control straight in front
of the sensor at a distance of about 4"(10cm). Choose the function you want to adjust by pressing
once on one of the function buttons. After pressing once on a specific function button, a quick
flashing of the red light at the front of the sensor will occur.
At this stage, you can change the adjustment by pressing the (+) or (-) buttons,
every push will increase or decrease one level.
Range:
Press + to increase the detection range and – to decrease the detection
range of the sensor.
The remote control can also be used to adjust:
Flow Time (Security time):
Press + to increase the security time and – to decrease it.
Delay In:
Changes the time the water will start flowing when the user's hands are within the
sensor range. Press + to increase it and – to decrease.
Delay Out:
Changes the time of water flow after the user's hands are removed. Press + to increase
it and – to decrease.
On/Off:
Press this function button and the faucet will remain off for 1 minute. To cancel this
function press the on/off button again.
Reset: