background image

 

4. Install the 20 micron sediment filter, 5 micron sediment filter and activated carbon filter in filter housings. 

 

5. Connect 

3/8” feed water to inlet of cartridge filter housing. 

6. Connect 

¼” drain tubing to drain port of RO unit. 

7. Connect 

¼” PERMEATE (product) water tubing from carbon post filter tee fitting to storage tank (not 

provided)  

8. Connect ¼” PERMEATE (product) water tubing from carbon post filter elbow fitting to desired point-of-use. 

 

 

 

 

 

 

 

1.  Turn on feed water to RO system. 

2.  Use the red pressure relief buttons on the top of ALL of the cartridge filter housings to purge air out of the 
canisters. 

3.  Apply 110v power to unit. 

4.  Inlet valve will open and pump will start running.  Reverse osmosis unit will Auto Flush a high flow of water to 
the drain for 60 seconds.  The following lights should be illuminated on the control panel: 

 

‘POWER’  ‘LOW WATER’  ‘PRODUCING’  ‘FLUSHING’ 

5.  After the flushing cycle, slowly close the PRESSURE REGULATOR adjustment knob (turn clockwise) on the 
drain line and monitor the concentrate and permeate water flow. 

6.  Continue adjusting the PRESSURE REGULATOR until the flow of the PERMEATE (product water) line is ½ 
of the flow of the CONCENTRATE (drain water) line.   

 

Note: High TDS water may not allow the 1:2 ratio of product water to drain water listed.   

7.  Allow the unit to fill the storage tank (not provided).  When storage tank is full the pump will stop and the 
“POWER’ and ‘LOW WATER’ lights will remain illuminated.  

 

 

 

START UP 

INSTALLATION (continued) 

Содержание SRO-300

Страница 1: ...1 SRO 300 INSTALLATION MANUAL 12630 US 33 N Churubusco IN 46723 Ph 260 693 1972 Fax 260 693 0602 www sterlingwatertreatment com ...

Страница 2: ... hardness This unit is not supplied with a storage tank but may be used with either an atmospheric non pressurized or pressurized style tank If an atmospheric storage tank is used a float switch must be used to turn power off to the system 1 Disconnect tubing and remove end cap from membrane housings 2 Install membranes in housings The brine seal around the membrane must be on the inlet side of th...

Страница 3: ...nlet valve will open and pump will start running Reverse osmosis unit will Auto Flush a high flow of water to the drain for 60 seconds The following lights should be illuminated on the control panel POWER LOW WATER PRODUCING FLUSHING 5 After the flushing cycle slowly close the PRESSURE REGULATOR adjustment knob turn clockwise on the drain line and monitor the concentrate and permeate water flow 6 ...

Страница 4: ...le PRODUCING Light indicates the reverse osmosis unit is producing water LOW WATER Light indicates adequate feed water pressure NO Light indicates low feed water pressure POWER Light indicates unit is supplied with electrical power Sediment Filter GB2020 Sediment Filter GB2005 Carbon Filter CB2005 Membrane TFM 100 x3 Carbon Post Filter IC10T CONTROLLER REPLACEMENT FILTERS ...

Страница 5: ...anty Not Cover This warranty does not cover the disposable sediment and carbon filters whose service life depends on feed water conditions In addition the membrane is only warranted if the required feed water conditions are met The above warranty will also not apply to any part of the R O Drinking Water System that is damaged because of neglect misuse alterations accident misapplication physical d...