3
4. Install the 20 micron sediment filter, 5 micron sediment filter and activated carbon filter in filter housings.
5. Connect
3/8” feed water to inlet of cartridge filter housing.
6. Connect
¼” drain tubing to drain port of RO unit.
7. Connect
¼” PERMEATE (product) water tubing from carbon post filter tee fitting to storage tank (not
provided)
8. Connect ¼” PERMEATE (product) water tubing from carbon post filter elbow fitting to desired point-of-use.
1. Turn on feed water to RO system.
2. Use the red pressure relief buttons on the top of ALL of the cartridge filter housings to purge air out of the
canisters.
3. Apply 110v power to unit.
4. Inlet valve will open and pump will start running. Reverse osmosis unit will Auto Flush a high flow of water to
the drain for 60 seconds. The following lights should be illuminated on the control panel:
‘POWER’ ‘LOW WATER’ ‘PRODUCING’ ‘FLUSHING’
5. After the flushing cycle, slowly close the PRESSURE REGULATOR adjustment knob (turn clockwise) on the
drain line and monitor the concentrate and permeate water flow.
6. Continue adjusting the PRESSURE REGULATOR until the flow of the PERMEATE (product water) line is ½
of the flow of the CONCENTRATE (drain water) line.
Note: High TDS water may not allow the 1:2 ratio of product water to drain water listed.
7. Allow the unit to fill the storage tank (not provided). When storage tank is full the pump will stop and the
“POWER’ and ‘LOW WATER’ lights will remain illuminated.
START UP
INSTALLATION (continued)