IMC24
IMC30
IM24
IM30
IM45
IM60
IM75
MEDIA VOLUME (ft
3
)
0.75
1.0
0.75
1.0
1.5
2.0
2.5
CAPACITY (grains)
@Minimum Salt Setting (6#/ft
3
)
13,500
18,000
13,500
18,000
27,000
36,000
45,000
@Factory Salt Setting (9#/ft
3
)
15,750
21,000
15,750
21,000
31,500
42,000
52,500
@Maximum Salt Setting (15#/ft
3
)
24,000
32,000
24,000
32,000
48,000
64,000
80,000
SERVICE FLOW RATES (gpm)
Continuous
8
10
8
10
12
15
18
Peak
12
15
12
15
18
20
22
PRESSURE LOSS (psi)
2
@ Continuous Flow Rate
5
7
7
8
9
10
12
@ Peak Flow Rate
12
20
18
20
20
22
24
REGENERATION FLOW RATES (gpm)
Backwash
2.2
2.2
1.3
1.7
2.2
3.2
4.2
Brine Draw and Slow Rinse
0.27
0.27
0.27
0.27
0.27
0.38
0.38
Rapid Rinse
2.2
2.2
1.3
1.7
2.2
3.2
4.2
FACTORY REGENERATION SETTINGS
Brine Fill (# of salt)
6
9
6
9
13.5
18
22.5
Softening (minutes)
90
90
90
90
90
90
90
Backwash (minutes)
6
6
6
6
8
10
12
Brine & Rinse (minutes)
45
45
45
45
50
55
60
Rapid Rinse (minutes)
4
4
4
4
6
6
6
Total Water Used (gallons)
34
34
25
29
44
72
98
DIMENSIONS (in.)
Mineral Tank (diameter x height)
10 x 35
10 x 35
8 x 44
9 x 48
10 x 54
12 x 48
13 x 54
Brine Tank (diameter x height)
11 x 11 x 34 11 x 11 x 34
18 x 33
18 x 33
18 x 33
18 x 33
18 x 33
Overall (length x width x height)
11 x 21 x 43 11 x 21 x 43 18 x 26 x 52 18 x 27 x 56 18 x 28 x 62 18 x 30 x 56 18 x 31 x 62
GENERAL REQUIREMENTS:
Water Temperature
33°F - 100°F
Water Pressure
25 - 100 psi
Electrical Requirements
110v/60hz
Electrical Current Draw
0.5 amps
Maximum Iron Concentration
3
≤ 2.0 ppm
Notes:
1.
2.
3.
Pressure loss information is approximate. Actual pressure loss may vary
depending on water quality, temperature, gallons used since last regeneration,
etc.
Water softeners can be expected to remove reasonable amounts of clear water
(ferrous) iron only. For best results an iron filter is recommended. Anytime red
water (ferric) iron or iron bacteria is present an iron filter is required.
UNIT MODEL NUMBER
1
Unit models listed include 3/4" Q-Tite plumbing connections. If 1" elbow
connections are required use "-1" as suffix to the unit model number (i.e. IM30-1).
SPECIFICATIONS:
18
Содержание IM Series