22
current scale when the weight is less than 1/5 of one
graduation from center zero. This feature allows for
correction of zero drift due to load cell drift,
temperature changes, or deadload drift(dust,
evaporation,etc). Use zero tracking only if counting
parts which individually weigh more than 0.2 scale
graduations. Select:
t(rue) - To enable zero tracking
F(alse) - To disable zero tracking
05
DA LO
Digital Averaging
Digital averaging is used to stabilize the displayed
weight or count by continually averaging weight
readings. Use medium or high digital averaging if
the scale environment includes substantial mechanical
vibration or air currents. Use low digital averaging
if fast responses to changes in load are required
(i.e. fast filling operation). Select:
LO - For low averaging(less stable) and faster
display updates(faster response).
MEd - For Medium averaging and displayed updates.
HI - For High averaging(more stable) and
slower display updates(slower response).
06
unit lb
Unit of Weight
Selects the unit of weight for display and data
output. Select:
lb - If using pounds for unit of weight
Kg - If using Kilograms for unit of weight
gr - If using grams for unit of weight
07
BAnd 0.02
Motion Band Width
Selects the amount of scale motion(in fractions of
a displayed grad) allowed when zeroing or measuring
an APW when sampling. Lower motion band values will
give more accurate piece counts, while higher values
allow for greater vibration. Select the lowest
motion value which give a reasonable settling time.
Select:
0.02 - Motion band will clear with less than 0.02
graduations motion.
0.10 - Motion band will clear with less than 0.10
graduations motion.
0.20 - Motion band will clear with less than 0.20
graduations motion.
0.30 - Motion band will clear with less than 0.30
graduations motion.
08
SAMPSL t
Sample Select Variable or Selectable Sampling