Quick Guide to the
buttons on the front panel.
Refer to Pages 8 - 11 for in depth procedure
To operate the Pro Batt Ultra
refer to page 7 (next page)
for instructions.
Force unit to float. On/off toggle.
Turn unit on / off toggle.
Battery type select.
Change Operational on/off voltages
Reset unit to default.
30+
20+
Toggle Power Supply mode
(provides live output voltage)
15+
Display software version
SVEM*
Stationary Vehicle Engage Mode
15+
SVEM*
Stationary Vehicle Engage Mode
Pro Batt Ultra starts charging when input is >13.1V.
Turns off when input is <13.0V.
30+
OEM* lock
- disables further
adjustment of unit’s functions
OEM lock - press Setup button for 30+ seconds -
4 x red LEDs should light to confirm.
repeat procedure to remove the lock.
this mode prevents operators tampering with the unit’s
settings when in the field. The OEM / fitter can set the
unit up as they desire first, the settings shall be stored,
then they can apply this lock.
Guide to buttons
Press Length (s)
Action
2-5
Forces unit into float mode. Press again to take out of float mode.
5-10
Turns unit on / off toggle.
10-20
Battery type select - use SETUP / SELECT to toggle between types. Both to confirm.
20-30
Change operational on/off voltages - use both buttons to scroll between voltages.
30+
Reset unit to default - press and hold both buttons for 2 seconds to confirm.
Press Length (s)
Action
0-1
Change to status fault display / back to Voltage display mode.
5-10
Toggles between 1/2 and 1/1 (full) power.
10-15
Set Auto Regen. time - use either buttons to toggle between the preferred time.
15-30
Live output voltage (power supply mode) - press SELECT to change to LED 24.
30+
OEM lock
- disables further adjustment of unit’s functions.
Press Length (s)
Action
2-5
Night mode = 1/2 power for 8 hours, then back to full power.
5-10
Enter standby mode. To take out of standby, repeat.
10-15
Display software version (displayed in binary on display).
15+
SVEM
- Stationary Vehicle Engage Mode
7