Standard inverter with dual sockets.

Earth adjustable between centre tapped 

earth ( default ) and Neutral earth bonded 

(simply add rear fuse for neutral earth bonding) 

Pre-fitted RCD Model.

A 30 mA RCD pre-installed in unit 

pre-wired for neutral earth bonding

to operate RCD.  

Front view

Front view

Rear view

Rear view

Option 1

Option 2

6

1

2

3

4

13

11

10

9

8

7

5

12

14

1) UK socket

7) USB charger 

2) Euro socket 

8) On / off ( remote control )

3) Power LED Green, 

on

 when inverter is Live. 

9) Positive cable or positive connector in larger units 

4) Fault LED Red, if 

on

 there is a fault.

10) Negative cable or negative connector in larger units 

5) LED display ( -P- = Power, watts , not usable on low 

11) Link for converting to neutral earth bonding 

power loads, about +/- 10%, not very accurate just 

12) Earth to chassis 

approx ) 

13) Residual Current Breaker ( earth trip )

    ( -U- = Voltage ( input DC ) = +/- 0.2V)

14) Pre-wired AC output cable  

    Fault Display  i.e. 05 then unit over heat, restart 
manually 
6) Remote control ( optional )

Fault                        LED light           Alarm        AC output                   Reset required

Low input voltage        Green on red off        Yes                  Yes                     alarm stop when voltage increase
     Warning 
 
Low input trip              Green on red on         Yes                  No                        Charge batteries then switch unit off
                                                                                                                                   and on to restart 
High input voltage       Green on red on         No                   No                       Reduce input voltage then switch
                                                                                                                                    off and on again to reset 
Overload  Shutdown   Green on red on         No                   No                         Reduce load, switch off and on to
                                                                                                                                                 restart
Over Temp shut          Green on red on         Yes                    No                       Unit must return to temp then switch 
                                                                                                                                        off and on to restart 
Short circuit                Green on red on          No                   No                        Remove short unit will be on 

Specification          300 watt         600 watt       1000 watt     1600 watt     2000 watt

Input voltage                                  12V model ( DC 11-15V )     24V model ( DC 22-30V )
Output voltage                                            230V +/- 10%   or 110V +/- 10%
Output frequency                     230V version 50 Hz +/- 3 Hz      110V version  6
USB port                                                                    DC 5V, 500 mA  
Continuous power           300W                 600W              1000W               1600W             2000W
Peak Power                     600W               1200W              2000W               3200W            4000W 

Digital display                                        Input voltage and unit power in watts  
Output wave form                                                       Pure sine wave
Distortion                                                                             < 5%
Efficiency                                                                             > 85%
No load Quiescent current                                                    0.95A
Low voltage alarm (nominal)                              12V =  10.5 V       24V = 21 V
Low voltage trip    (nominal)                               12V =    9.5 V       24V = 19 V
High voltage trip   (nominal)                               

             

0 Hz +/- 3 Hz

12V =  15.5 V       24V = 31 V

Fan Operation, the fan will come on in the event of power exceeding 30% of unit rating or the internal exceeds 60C 

Fuse Recommended     12V   60A       
use Sterling ANL fuse    24V   30A        24V   50A         24V   70A           24V  125A       12V   180A   

12V   100A       12V   150A          12V  250A       12V   350A   

Fig 1

Fig 2

Содержание SIB121000

Страница 1: ...watt Twin sockets interchangeable between both Optional extra 4 1 kg 190x85x300L 8 mm connection SIB242000 12V 1000 watt with RCD Optional extra 3 5 kg 190x85x330L 8 mm connection SIBR121000 12V 1600 watt with RCD Optional extra 3 6 kg 190x85x330L 8 mm connection SIBR121600 12V 2000 watt with RCD Optional extra 4 1 kg 190x85x330L 8 mm connection SIBR122000 24V 1000 watt with RCD Optional extra 3 5...

Страница 2: ...top when voltage increase Warning Low input trip Green on red on Yes No Charge batteries then switch unit off and on to restart High input voltage Green on red on No No Reduce input voltage then switch off and on again to reset Overload Shutdown Green on red on No No Reduce load switch off and on to restart Over Temp shut Green on red on Yes No Unit must return to temp then switch off and on to re...

Страница 3: ...ion switch Option 2 Type with Pre wired RCD 230V AC earth to vehicle chassis or boat bonding system Live Earth Neutral Fig 3 Fig 6 Fig 5 Fig 4 Optional remote control with 10m cable Optional remote control with 10m cable RCD Residual earth detector Breaker earth leak detector Pre fitted RCD Installation for Option 1 twin socket product All electrical installations should be carried out by a profes...

Страница 4: ... connected this lead will become live if not switched off this is high voltage AC and could kill This unit comes standard as centre tapped and must be converter to neutral earth bonding before installation Ensure the Neutral bonding link is connected small fuse in position 11 in fig 1 same position on Fig 2 remove the cover and insert the small fuse in that link the unit is supplied without that l...

Страница 5: ...att Deux prises interchangeable entre les deux Option 2 0 kg 190x85x300L 1m DC 8 mm ring SW241000 24V 1600 watt Deux prises interchangeable entre les deux Option 3 6 kg 190x85x360L 8 mm connection SW241600 24V 2000 watt Deux prises interchangeable entre les deux Option 4 1 kg 190x85x400L 8 mm connection SW242000 12V 1000 watt avec DDR Option 2 0 kg 190x85x300L 1m DC 8 mm ring SWR121000 12V 1600 wa...

Страница 6: ...rée Verte on rouge on oui non Charger la batterie puis éteindre trop basse et rallumer l appareil Tension entrée haute Verte on rouge on Non Non Réduire la tension entrée éteindre l appareil et le rallumer Coupure surcharge Verte on rouge on Non Non Réduire la charge éteindre et rallumer pour redémarrer Coupure température Verte on rouge on oui Non L appareil doit revenir à une température haute n...

Страница 7: ...fusible Sterling GANL muni du fusible correct GANL voir spécifications Batterie _ Interrupteur isolant Sterling Option 2 Système DDR précâblé 230V CC Terre vers le chassis du véhicule ou la ligne de terre du bateau Phase Terre Neutre Fig 3 Fig 6 Fig 5 Fig 4 Ecran de contrôle en option avec 10m câble Ecran de contrôle en option avec 10m câble DDR Disjoncteur différentiel Résiduel détecteur fuite à ...

Страница 8: ...e le convertisseur a une appareils utilisant le courant alternatifs du convertisseur Mettez tension adaptée à votre bateau ou à votre véhicule l interrupteur du convertisseur sur off Assurez vous que l interrupteur de 2 Assurez vous qu au moins 2 des 5 supports sont vissés sur la cloison l écran de contrôle est sur off Branchez alors l écran de contrôle à 3 Quand les câbles ne sont pas fournis App...

Страница 9: ... wechselbar optional 3 6 kg 190x85x300L 8mm Anschlussbolzen SIB241600 24V 2000W UK Deutsche Steckdose wechselbar optional 4 1 kg 190x85x300L 8mm Anschlussbolzen SIB242000 12V 1000 W mit 30mA FI Schutzschalter optional 3 5 kg 190x85x330L 8mm Anschlussbolzen SIBR121000 12V 1600 W mit 30mA FI Schutzschalter optional 3 6 kg 190x85x330L 8mm Anschlussbolzen SIBR121600 12V 2000 W mit 30mA FI Schutzschalt...

Страница 10: ...t Warnung Unterspannungs grün rot Ein Aus Batterien laden und Gerät a Überspannungs Aus Aus Spannung reduzieren und Gerät Überlastabschaltung Aus Aus Leistungsabnahme reduzieren und Gerät Übertemperatur abschaltung us und wieder einschalten grün rot abschaltung aus und wieder einschalten grün rot aus und wieder einschalten grün rot Ein Aus Gerät abkühlen lassen und anschließend aus und wieder eins...

Страница 11: ...ine Elektrofachmann ausgeführt werden Sollten irgendwelche Zweifel bestehen bitten wir um sofortige Kontaktaufnahme Installieren Sie dieses Produkt nicht wenn Sie nicht über die fachliche Qualifikation verfügen Hohe Spannungen sind lebensgefährlich 6 Befestigen Sie das Gerät installieren Sie die Sicherungen und Schalter 7 1 Montieren Sie das Gerät an einem trockenen kühlen und gut belüfteten Ort A...

Страница 12: ... wird über die Sicherung pos 11 fig 1 auf der Rückseite des Gerätes gemacht Dieses befindet sich unter dem Negativ Anschluss Öffnen sie die Schutzabdeckung und stecken Sie die beiliegende Sicherung in die Öffnung Anschließend verschließen Sie die Sicherung mit der Kappe Anschließend funktionert ein FI Mstellen Sie sicher dass das Gerät ausgeschaltet ist und auch der Customer Service Warranty Ihre ...

Отзывы: