this displays the output voltage and current of the 

battery you are charging. ( a less current but higher voltage ) 

( this is the setup information screen )  This screen gives different 

information depending on the system cycle, it is informing you., WET  OPEN= wet open lead acid cell batteries, 
this  shows that the  system battery type dip switches are set for wet cell batteries,( 14.8 v max setting ) Bulk 
charge refers to the initial charge rate, this could change to a timer, then adventually change to float ( float 
charger 14 volts )
                

  This screen shows the time left to the next pause cycle  

( for 2.5 min. ) and that it is on auto. The auto can be removed by pushing buttons 1 and 2 together. This 
removes the auto pause control, and the charger will still have all its safety and timing cycles, every 20 min. 
pause

 R:v2.0 C:v2.0, this shows the software version for 

remote ( R ) and for main PCB ( C ). the 12vIN-12vOUT, refers to the motel, a 12v-12v unit. There are 12-24 v, 
24-24 and 24-12.

:  There are 2 x screens on this button. Push once for screen a, then 

again for screen b. Screen a shows the alternator temp and the domestic battery temp, if the temperature 
sensors are not fitted it will default to 20 deg C

 Temp 4a+b:  There are 2 x screens on this button. Push once 

for screen a, then again for screen b. Screen b shows the box heat sink temperatures, LHS stands for left hand 
side, Guess what RHS stands for.

Do not expect these to be the same temperature

Pre set voltages: 
Minimum input voltage the unit will run at    13 volts
Voltage the unit switches off and drops into sleep mode 
           below 12.8 v for at lease 15 mins
Power consumption on sleep mode. 5 ma ie 0.005 amps
max input voltage trip 15.5
max output voltage trip 15.5

Alt temp disengage    100 deg C
Reset alt                        80
Battery temp trip           50 deg C
Heat sink trip                  70 deg C
Heat sink reset               60 deg C
Fans on at                     50 deg C
Fans on over                 35 amps 
Fans of at                       45 deg C
Low battery alarm          1 2.5 v
Low battery regulation    13 v 
high battery voltage trip 15.5v
Max input current  at 12 v = 45 amps
amp meter +/- about 10%
vol/- 1%

 Push button marked 2 again: screen E/b 

Screen F/a: Push button marked 3 

 Push button marked 3 again: screen F/b.

                Push button marked 3 again: screen F/c.

Screen G/a: 

 

Push button marked 4

.

                Screen G/b::  Push button marked

( x 2 for 24 v models )

All voltages refer to a default temperature of 20 deg c

if the battery temperature sensor is fitted these voltages will be less depending on 

the battery temperature

Содержание BATTERY-to-BATTERY CHARGER

Страница 1: ...Instructions manual Installations und Bedienungsanleitung BB121250 BB122430 REMOTE CONTROL OPTION ORDER NO BBDRC Battery Battery Charger Sterling power products CE on off 1 2 3 4 light alarm alarm Ala...

Страница 2: ...11 12 13 fig 8 NON SEALED LEAD ACID OR TRACTION LED YELLOW GEL EXIDE SPEC LED GREEN GEL USA SPEC LED OFF SEALED ACID AGM LED ORANGE ON 1 2 ON 1 2 ON 1 2 ON 1 2 BATTERY TYPE SELECTOR SWITCH SETTINGS S...

Страница 3: ...ng split charging system ie a bow thruster battery bank The dotted line shows the original system and how simple it is to connect the d c battery charger Standard simple installation for auxiliary cha...

Страница 4: ...stem o k 2 1 3 4 InBat v 13 7v Current 38A 20min ON 17min CHARGE BATTERY IN 13 7V 38A BATTERY OUT 14 2V 31A in 13 7V 23A out 14 4V BULK Remote control panel A B C fig 5 fig 6 WET OPEN BULK CHARGER Cas...

Страница 5: ...ruster then 2 of these can be used to run the bowthruster and the domestic system There internal programs will adjust their charger patterns to accept the other unit Ensure only the excess power is us...

Страница 6: ...unit senses all the control voltages at the unit however if you want to sense the voltage at the domestic battery direct to over come the voltage drops in the cable run drops then simply connect a ca...

Страница 7: ...s that the alternator should be working at it s maximum It should remain on until the green float comes on and this shows the high charge rate is complete TIMER ON Yellow Timer Activated This comes on...

Страница 8: ...bank by charging with as many other auxiliary charging systems as you can For example if you are running a gen set for 4 hrs per day you may as well put as much power as possible into your main large...

Страница 9: ...the temperature sensors are not fitted it will default to 20 deg C Temp 4a b There are 2 x screens on this button Push once for screen a then again for screen b Screen b shows the box heat sink tempe...