GP8002.A
1
719 622 7200
Sterisil.com
STERISIL
®
SYSTEM G4
INSTALLATION AND
MAINTENANCE MANUAL
Страница 1: ...GP8002 A 1 719 622 7200 Sterisil com STERISIL SYSTEM G4 INSTALLATION AND MAINTENANCE MANUAL ...
Страница 2: ...f any size office Whether it s 1 or 100 chairs our Dental Waterline Compliance Specialists can help you configure the system to fit your needs The G4 comes equipped with a suite of sensors monitors and indicators for convenient quality assurance and notification of system maintenance When the time comes both audible and visual alarms notify users of the issue to be addressed The standard G4 kit in...
Страница 3: ...he G4 can be installed nearly anywhere in the typical dental medical lab or hospital setting typically near a faucet and sink The system and tanks are designed to fit under a counter top but can be installed anywhere there is a quality cold water supply and drain connection Please locate the system s serial number on the left panel of the unit Record the installation date on the warranty card Plea...
Страница 4: ...4 pressure gauge x2 3 8 pressure gauge Flow Sensor Flow Restrictor modular couplers stem elbow x3 Dental Autoclave Discs cables and RJ 12 connectors Small bag 10x1 mounting screws x8 sheet rock plastic anchors x8 supply tee 1 4 union tee 1 4 Tank Ball Valve 3 8 Tank Ball Valve Inline Ball Valve and Single Check Valve BOX 2 Dental Water Storage Tank BOX 3 Reserve Water Storage Tank RESERVE WATER DE...
Страница 5: ...nks in desired locations A common location is under a sterilization center sink Take each tank and wrap the threads on top of the tanks with thread tape included Install the 3 8 valve and hand tighten it to the larger Reserve Tank Do not over tighten this valve Repeat this process with the 1 4 valve for the Dental Water Tank Ensure the pressure of the tanks is between 8 10 psi using a Schrader val...
Страница 6: ...lave Port Green fitting indicator Run 1 4 tubing from the green AUTOCLAVE port on the system to the white Autoclave Faucet Permeate Pump IMPORTANT The Permeate Pump must be mounted with the long arrow pointing up The Permeate Pump will not function properly if positioned sideways or upside down Run 1 4 tubing from bottom of Stage 3 to BRINE IN on the Permeate Pump Cut the tubing and insert the Flo...
Страница 7: ...ndar for the specific interval Close the inline ball valves before and after the housing Purge the pressure from the filter housing by depressing the red button on the top of the lid Unscrew the water reservoir lid to access and replace the micron filter inside Reassemble and open the inline and source water valves to restore flow to the system Visually confirm water is flowing freely OPERATIONAL ...
Страница 8: ... is tracked via the Filter Monitor on the far left side of the system When properly programmed the Filter Monitor tracks the remaining months of the cartridges and UV Light life STAGE 4 CARTRIDGES P N SS C4 OR SS DI SS C4 x2 Stage 4 Cartridge readings are based on the quality of water coming off them Water quality readings can be found on the far right monitor When the reading on the Water Quality...
Страница 9: ...in the trash or returned to Sterisil for recycling For more information on our recycling program visit sterisil com recycle 2 STERISIL RECYCLING PROGRAM Sterisil offers a free recycling program allowing customers to recycle their used Sterisil Cartidges by a click of a button Simply visit sterisil com green or call us directly to request a free shipping label While other companies dispose 100 of t...
Страница 10: ...16 GP8002 A 16 835 S HWY 105 SUITE D PALMER LAKE CO 80133 719 622 7200 WWW STERISIL COM ...