1
GP8002.A
GP8002.A
TABLE OF CONTENTS
INTRODUCTION
Introduction
Optional
Add-ons
Specs
Before
You
Begin
Specifications
Overview
Diagram
Phase
1:
Unpacking
and
Inventory
Phase
2:
Mounting
and
Peripheral
Components
Phase
3:
Cartridges
Phase
4:
Source
Water
and
Tubing
Phase
5:
Electrical
and
Operational
Test
Optional
Add-ons
Maintenance
Manual
Sterisil
®
Limited
Warranty
DOCUMENTS LOCATED AT WWW.STERISIL.COM/STERISIL-SYSTEM
Filter Monitor Ideal Readings and Operation
Water Quality Monitor Ideal Readings and Operation
Congratulations! What you see before you represents the accumulated knowledge of almost 20 years
of Sterisil
®
dental waterline purification and disinfection techniques. The Sterisil
®
System G4 merges
the best water purification methods available with our silver-based ion exchange technology. The final
product is the only dental water purification system EPA registered to produce treated dental water and
autoclave water.
The 6 unique stages of purification and disinfection include reverse osmosis, deionization, Class B
ultraviolet (UV) disinfection, and our proprietary residual silver disinfectant. Treated dental water is non-
toxic, non-corrosive, contains no oxidizers, and is safe for patients, staff, and equipment.
Treated dental water is EPA registered and carries with it a quantified disinfection claim of
≤
10CFU/ml
HPC purity. That’s 50 times lower than the ADA and CDC guidelines without tablets or daily additives.
The G4 is completely scalable and capable of fulfilling the water needs of any size office. Whether it’s
1 or 100+ chairs, our Dental Waterline Compliance Specialists can help you configure the system to
fit your needs. The G4 comes equipped with a suite of sensors, monitors, and indicators for convenient
quality assurance and notification of system maintenance. When the time comes, both audible and
visual alarms notify users of the issue to be addressed.
The standard G4 kit includes storage tanks, tubing, cartridges, and mounting hardware needed to
complete your installation. The G4 is backed with a 1-year limited warranty including remote support from
our team of expert dental waterline technicians. Visit sterisil.com/sterisil-system for the latest updates.
Welcome to the next level of water compliance peace of mind and confidence with your new G4.
OPTIONAL ADD-ONS:
Sterisil offers optional add-ons to the G4 to ensure proper performance. Installation of these items can
be found on pages 11-12. Optional add-ons are identified in each relevant section by the color purple.
Specific requirements for add-ons must be understood before starting the installation.
ADD-ONS INCLUDE:
NEED HELP OR HAVE QUESTIONS
Our technical support staff is available and
ready to help. Please call, email, or visit us
online for additional support.
719 622 7200
sterisil.com
835 S Highway 105 Suite D
Palmer Lake, CO 80133
Fax: 866 299 2495
1
1
2
3
4
5
6
7
8
9
11
13
15
Optional Add-on Components
Pre-filter Kit
(5”Dia x 12”H), Suggested use with source water quality > 250 PPM TDS
Booster Pump
(4”Dia x 7”H), Suggested use with source water pressure < 60 PSI
Sterisil
®
Wand
Autoclave must be within 10’ of the system
EPA Establishment No.: 83315-CO-001
EPA Reg. No. for Residual Disinfection: 83315-2