3.2 Electrolysis cell 

 
 
 
 
 
 
 
 
 
 
 
Dimensions: 
Length 275 Height 180 mm Depth 152 mm. 
 

Each cell has two PVC end fittings with 

inside diameter of 50 and outside diameter of 
63.  These  end  fittings  must  be  affixed  to  the 
by-pass on the filtration circuit using PVC glue. 

 

 
Assemble  the  electrolysis  cell  in  by-pass  as 
shown  in  the  diagrams  above  with  three 
valves,  on  the  backflow  circuit  (return  to  the 
swimming  pool),  after  the  filter,  after  any 
analysis 

electrode 

and 

any 

booster 

compressor or heating outgoing cable. 
 
However,  the  cell  can  be  assembled  without 
by-pass  on  installations  with  a  pump  with 
power below 1 hp. 
 
 
Warning,  the  bypass  valves  must  be  open  to 
allow  the  water  to  pass  through  the 
electrolysis cell before STERILOR Sel is started 
up. 
 
The  electrolysis  cell  must  be  under  a 

flow  of 

water

 when STERILOR Sel is operating. 

 
 
The  cell  should  preferably  be  installed 
horizontally,  at  45°  towards  the  top.  This 
orientation  ensures  the  evacuation  of  water 
that  may  appear  on  the  cap  (condensation, 
splashing, etc.) 
 
Effectively, the electrode connectors must not 
be  in  contact  with  water.  Non-compliance 

with  this  guideline  may  result  in  premature 
corrosion  of  the  connectors  and  premature 
deterioration of the cell. 
 

 

 

 
 
 
 
 
 
 
 
 
Titanium  electrodes  coated  with  precious 
metal oxides: 
 

Place  the  electrode  with  its  seal  in  the 
electrolysis cell. 
 
 
 
 
 
 
Rotate  it  on  its  support  to  wedge  it  correctly 
so  that  the  water  circulates  between  the 
electrode's plates as indicated on the diagram 
below.  
 

The water must flow between the electrode's 
plates. The flow of pool water must arrive on 
the section of the plates and not opposite the 
plates. 

 

Electrode  connections  Connect  the  cable 
provided  for  this  purpose  to  the  box,  quick 
connectors. 
 

3.3 Cover Connection or Servocontrol 

Connection: 

Quickly  connect  the  connector  to  the 

left-hand  lateral  connector  provided  for  this 
purpose,  see  point  2.1.4.  (

Important:  this 

contact must absolutely be a dry contact - not 
connected to the power supply

  

 

 

 

 

Orientation 

of the cell 

45° from the 

vertical 

Содержание Sel

Страница 1: ...1 AUTOMATIC SALT ELECTROLYSIS WATER TREATMENT SYSTEM Installation Instructions User Guide Please read carefully and keep available for later use Version 11 2013 SR 12 163 4GB STÉRILOR Sel ...

Страница 2: ...2 ...

Страница 3: ...r a long time for optimised installation and operation of all of the equipment for your new electrolyser Read it carefully before use in order to fully benefit from all of its functions By using STERILOR Sel with a pH that is well regulated around 7 your pool s water will be perfectly disinfected You can regulate your pH manually or automatically by having a STERILOR pH installed USEFUL ADDRESS Yo...

Страница 4: ...f the box 8 2 1 4 Lateral sides of the box 9 3 INSTALLATION 9 3 1 Control box 10 3 1 1 Location attachments 10 3 1 2 Location 10 3 1 3 Electric connections 10 3 2 Electrolysis cell 12 3 3 Cover Connection or Servocontrol 12 3 4 Flow rate detector 13 4 USE 14 4 1 Memo 14 4 1 1 pH 14 4 1 2 Chlorine 14 4 1 3 Salt 14 4 1 4 Stabiliser 15 ...

Страница 5: ...aying the change in polarity 16 4 4 2 Operating the change in polarity 16 4 5 Displaying device operating time and hours 17 4 6 Cover servocontrol Slow mode 17 4 6 1 Displaying and operating the Slow Mode 17 4 6 2 Manual setting of the production percentage with the cover in closed position 18 4 7 Servocontrol to a chlorine analysis 18 4 8 Displaying the diagnoses 19 5 WINTERISATION 20 6 EARTHING ...

Страница 6: ...ctrolysis cell When adding salt for the first time in the pool or on each addition the box and STERILOR Sel must be switched off for 24 hours so that the salt is totally dissolved Thedevice must be stopped as soon as the water temperature falls below 15 C Effectively at this water temperature the titanium electrodes coated with precious metal oxides produce more oxygen and hydrogen than chlorine D...

Страница 7: ...ts you from having to add chlorinated products All you have to do is maintain the water s pH between 6 9 and 7 4 STERILOR Sel is compatible with all current swimming pool liners and it adapts to any existing or new filtration systems Warning Salt is incompatible with metal filtration systems When adding salt to the pool for the first time or during each subsequent addition STERILOR Sel must be swi...

Страница 8: ...between 0 and 65 Display of device operating time Time display Display of polarity and countdown of the polarity Forced Operation indicator Automatic Operation indicator Swimming pool inflow Swimming pool backflow Earth towards separate earthing rod Towards drains Towards booster compressor heating robot Filtration box pH liquid injection salt electrolysis cell installed STERILOR Sel GENERAL PRESE...

Страница 9: ... thoroughly it is also advisable to replace the sand Connectors electrolysis cell cable General power supply fuse holder T 3 15 A ON OFF switch of the device Connection Cover or Servocontrol Connection Flow rate sensor Swimming pool inflow Swimming pool backflow Earth towards separate earthing rod Towards drains Towards booster compressor heating robot Filtration box pH liquid injection salt elect...

Страница 10: ...ng machine and 6 mm drill bit suitable for the support plugs supplied plastic expansion plugs to be adapted to the support if necessary Phillips screwdriver 3 1 3 Electric connections The system operates in parallel with the filtration pump It must operate at the same time as the filtration system A box continuously connected to a separate socket will annul the guarantee Before carrying out any el...

Страница 11: ...ation box Three phase filtration box STERILOR Sel STERILOR Sel MONO Auto Op Forced Op Circuit breaker Contactor Clock NEUTRAL PUMP EARTH Auto Op Forced Op Circuit breaker Contactor Clock NEUTRAL PUMP EARTH 380 V THREE PHASE ...

Страница 12: ...op This orientation ensures the evacuation of water that may appear on the cap condensation splashing etc Effectively the electrode connectors must not be in contact with water Non compliance with this guideline may result in premature corrosion of the connectors and premature deterioration of the cell Titanium electrodes coated with precious metal oxides Place the electrode with its seal in the e...

Страница 13: ...on of flow It can be assembled on a horizontal or vertical pipe Vertically the flow rate must be as high as possible to deactivate the loss of flow information Be careful to allow the movement of the blade a 24 mm diameter hole must be made in the tube before positioning the saddle tee To ensure the watertightness of the saddle tee mark out the position of the saddle tee on the tube before install...

Страница 14: ...nufacturers of these products 4 1 2 Chlorine The ideal active chlorine level is around 0 3 to 0 4 mg l ppm as soon as the water temperature reaches approximately 15 to 20 C Whenever the device is used with water that does not contain chlorine carry out manual chlorination For 100 m3 of water 300 g per day for 8 days 4 1 3 Salt The salt level must be 5 g l or 5 kg m3 The salt level should be analys...

Страница 15: ...royed by UVs 4 2 Production setting 4 2 1 Displaying and adjusting the production The amount of Chlorine produced depends on the salt level water temperature and quality and the device s operating time i e the filtration time The consumption of chlorine depends on the water quality contamination of the pool its level of use the environment and the climatic conditions Average operating settings in ...

Страница 16: ...shock treatment 4 3 2 Forced Operation activation and deactivation procedure The forced operation is activated by pressing on the Forced Operation key F key for 5 seconds The red Forced Operation light comes on and the Forced Operation text appears The production then changes to 200 Leave the equipment to operate for a maximum of 24 hours and carry out manual analysis of the level of chlorine in o...

Страница 17: ...ime press on the H button hours minutes for 5 seconds the hours display flashes Press on or to change them Press again on H hours minutes and the minutes flash Press on or to change them Finally press on H to store the time in memory 4 6 Cover servocontrol Slow mode 4 6 1 Displaying and operating the Slow Mode STERILOR Sel is equipped with the Slow Mode option for modulating the production of chlo...

Страница 18: ...left hand lateral side of the device Activation of the Chlorine Regulation mode Press on the and keys at the same time until the bubbles around the Chlorine production text disappear the chlorine measurement servocontrol mode is activated Active chlorine Servocontrol mode Inactive chlorine Servocontrol mode When the chlorine analysis redox or other is below the threshold configured the Electrolyse...

Страница 19: ... This analysis appears when the device recognises poor conductivity between the electrodes It then displays on the chlorine production display The cell is disconnected or not connected properly or oxidised Check the connection The electrodes are scaled up Clean the electrodes ACIDULOR recommended cleaning fluid The amount of salt in the water is too low Check the salt level 5g l D0033 After 6 000 ...

Страница 20: ... ABS or other plastics The linings are often made of polyester PVC liner or painted These types of swimming pools of which all of the components are made of plastic have the characteristic of storing static electricity Also the pump turbines create fairly significant static currents A filtration pump thus creates a variable voltage of approximately 3 to 4 Volts The same applies for counter current...

Страница 21: ...fore any intervention However periodic cleaning of the equipment with a dry cloth is recommended do not use aggressive chemicals that could damage the equipment particularly on the transparent part of the front face As with all electrical equipment a certain number of periodic checks must be carried out every quarter check of the electrical connections check of the conditions of the cables 8 STORA...

Страница 22: ...This device is guaranteed against any manufacturing defect for 3 years from the delivery date The user must contact his retailer according to the after sales service procedure Cut off the guarantee card opposite without forgetting to make a copy before sending it duly completed to the following address The guarantee card below must be returned to us no later than 15 days after commissioning of the...

Страница 23: ...must be provided for the guarantee in order to be taken into account Pool volume m3 Water source Public supply Borehole Well Rain pH Regulated pH device Filtration flow rate m3 h Stabiliser ppm Treatment used TA Total Alkalinity French degrees Type of heating TH hardness measurement French degrees pH corrector product used Trade name Chemical nature Pool Indoor Outdoor Cover Shelter Automatic cove...

Отзывы: