11
11.2 Fitting the box
• The box must be installed in a sheltered technical room.
• The box must be protected from direct sunlight and the elements.
• The room must not be damp, to prevent oxidation.
• No corrosive products should be kept near the box.
• The box must be installed vertically.
• Box installation height: about 1.50 m.
• Max. distance between the box and the cell: 1.80 m
• Leave free access to the connections on both sides of the box.
• The drill hole spacing to fix the box is: H 230 mm; L 220 mm.
• Drill 4 diameter 6 mm holes to fit the nylon anchors.
• Do not place anything on the box, to favour air flow (cooling).
• The electric connection must be made by a qualified person.
• Cut off the power supply before any connection.
• Provide a 6A circuit breaker coupled to the pump contact for the
electrolyser connection.
• When the filtration pump is stopped, the electrolyser must also
be stopped (Couple the electrolyser electric connection to the
filtration).
11.3 Box electric connection
Important:
Qualified staff for electric connections.
Cut off the electricity supply before connecting.
Single-phase filtration box:
Neutral
Phase
Earth
A.
Auto Op.
Forced Op.
PUMP
SINGLE
Circuit breaker
Connector
Clock
Three-phase filtration box:
Connector
Circuit breaker
Clock
Auto Op.
A.
Forced Op.
PUMP
380V THREE-
PHASE
Earth
Neutral
Phase
Stérilor cell
Filtration unit
230 Vac