“PLUS” Systems incorporating BA-ICE-SM controller:
The Silver “PLUS” series of products incorporate a UV sensor which detects the
discrete 254 nm wavelength of the UV lamp. This information is relayed to the
Silver “PLUS” controller and is the default display shown in “% UV output”. The
system will display the UV output between 50 to 99 percent. When the system
drops below 50%, a low UV warning is displayed as and alternately flashes
(at 2 second intervals) back to the actual UV level. Eg.
Additionally, the system will supply an intermittent audible tone (2 seconds on, 2
seconds off), during low UV conditions.
Note: UV levels of ...
1.
UV intensity (%):
Indicates the system is functioning within normal a normal operating range.
to
Indicates the UV level is still within a safe level, however at this level the
system should be examined to determine why the UV level is this low.
to
Indicates the UV level is nearing the point of unsafe UV intensity, at this level
the system should be CLOSELY examined to determine why the UV level is
this low.
to
Indicates the UV level has now reached a level that is unsafe. At this level
the water should not be consumed. The system/water supply should be
examined to determine the reason for the low UV level of the UV intensity.
At this level, the solenoid output has been activated and if a solenoid is
installed, water will cease to flow.
<
DEFERRAL
- To temporarily defer the audible alarm during a low UV alarm, press the
push-button “RESET” switch and hold for five seconds. This will mute the audible
alarm condition for 12 hours.
This advanced warning system has been installed to provide you
with the optimum protection against microbiological
contamination in your water.
DO NOT DISREGARD THE WARNING SIGNALS.
The best way to ensure optimum UV performance is to have the
water microbiologically tested by a recognized testing agency
on a regular basis.