background image

PREFS Mode____________________________________________________________________________________________14

8. PREFS Mode

To get into the Programmer's preferences hold SYNC for 2 seconds. You will see a little countdown displaying the

currently selected midichannel. Lifting the button before the countdown's end cancels entering PREFS mode and 

you find yourself –- yes –- in PLAY Mode again.
PREFS Mode offers 2 settings:

Midichannel of the Programmer

For Programmer and Pulse to work perfect they need to be

set to the same midichannel. Change the channel of the

Programmer with Encoder 4. 

The Pulse's channel is set in „GLB – MIDI Channel“.

Or you simply send a midinote into the Programmer on your

desired midichannel. 

Count of connected Pulses

In most cases this value will remain on 1. It comes into play if

you want to use multiple Pulses in a cascade to get a

polyphonic Pulse. See 

Chapter 10. Cascading

 for details.

Change the count of Pulses with 2nd or 3rd encoder.
In case you ask yourself why the Programmer has to know

how much Pulses are connected … as soon as the Pulse count

exceeds 1 there are 2 things changing in the Programmer:

Env Trigger screen shows the additional parameter 'PLY' or 'UNI'. You can select if your cascade should 

be played polyphonically or as a unison monstersynth with many (… maybe many, many) oscillators..

if the Programmer receives a Program Dump, it will be passed thru to MIDI OUT. All cascaded Pulses 

connected in the MIDI THRU chain will receive it and play the same program.

Exit

Press 

XIT

 to leave PREFS Mode. I you changed anything in this mode it will be saved in the Programmer's 

memory.  

Synth Programmer for Waldorf Pulse – Operation manual V 1.0 – 01/2018

© Stereoping Germany, Meschede 2018

Содержание Waldorf Pulse 1

Страница 1: ......

Страница 2: ...lse itself 7 Drive 7 Envelope Trigger 1 2 8 All Notes Off Panic 8 Portamento knob 8 Paraphonic Modus 8 5 MODULATION Mode 10 The 7 pages of the Modulation Mode 10 Knobs and the Modulations Sources they select keep MOD pressed 10 Knobs and the Modulation Destinations they select keep MOD pressed 10 Modulation Macros 11 6 Sync Mode 12 7 E Patch Mode 13 If you press LOAD 13 If you press SAVE 13 8 PREF...

Страница 3: ...APHONIC Mode Highly simplified access to the 6 Modulations Slots Unison mode for cascaded Pulses Technical handling The Synth Programmer was built to be used in a comfortable music studio environement You can operate it under free skies of course But please keep in mind it uses electricity for proper operation and therefore is quite sensitive to water drinks or other fluids Excessive heat or expos...

Страница 4: ...letter combination AC AC or a sinewave symbol besides the word output Midi connections The Stereoping Programmer has 3 Midi jacks which should be cabled like that MIDI 1 OUT MIDI IN of your Pulse MIDI 1 IN MIDI OUT of the Pulse MIDI 2 IN MIDI OUT of your Midi interface sequencers keyboards Both jacks of Midi 1 connect the Programmer with your synth in a loop This seems unconventional but it is nec...

Страница 5: ...lect a program on the Pulse then synchronize the Programmer with the Pulse Every time you want to begin editing another program you need to request it on the Programmer or dump it from the Pulse to the Programmer In cascading mode things are a little easier changing programs updates the Programmer automatically More about cascading in Chapter 10 Cascading Saving programs A program can be saved in ...

Страница 6: ...you enter SYNC Mode to sync the Pulse with the Programmer On pressing the function key REQ the Programmer requests the parameter data of the selected program number More on synching in Chapter 6 Sync Mode Note Programmer and Pulse can also be synched outside the Sync Mode by dumping the currently selected Pulse program manually from the Pulse press the Pulse buttons SHIFT MODE DUMP the Pulse s dis...

Страница 7: ...VCA Volume If you do not hear any sound although VCA Volume is up please check if maybe your DAW or keyboard turned midi volume down by CC 7 Altering parameter directly on the Pulse itself In case Programmer and Pulse are in sync you are sitting near the Pulse and the Programmer is on the other end of your huge studio you perfectly can change parameters on the Pulse itself The Programmer will be u...

Страница 8: ...or technical reasons You remember encoder 3 also can change values If you will need a porta time beyond 120 please use encoder 3 Paraphonic Modus You maybe already spotted the word Para near the Env Trigger modes If you turn the dial into that position no matter if Env 1 or 2 is active your Programmer turns your Pulse into a 3 voice paraphonic Synthesizer Means you can press 3 notes at once and pl...

Страница 9: ...more impact or change the balance of the intervals in a triad blend OSC 1 2 over to OSC 1 3 Each OSC can have it s own waveshape and be modulated individually by the mod matrix Nice example LFO1 with SQUARE WAVEFORM modulated OSC 1 Pitch to get a simple bassline OSC 2 is playing the melody line LFO 2 on pulsewith or used for a slight vibrato on pitch OSC2 from time to time play a 3rd note OSC 3 co...

Страница 10: ...can jump between the modulations slots and change AMOUNT at the same time Amount can be finetuned with encoder 3 Hint 2 by keeping MOD pressed you can select many SOURCES and nearly all DESTINATIONS directly thru the knobs with the same name The slots for Pitch 5 7 and Cutoff 6 7 logically only offer the selection of SOURCES Choose among the following knobs Knobs and the Modulations Sources they s...

Страница 11: ...ets of slot 1 4 set to Pitch 0 PWM for instant PWM Touch Slot 1 Pulsewidth of OSC 1 will be modulated by LFO1 with amount 40 Slot 2 Pulsewidth of OSC 2 will be modulated by LFO2 with amount 40 Slot 3 LFO1 Speed modulated by Keytrack with amount 40 Slot 4 empty LFO 1 rate set to 30 Waveform to Sine LFO 2 rate set to 40 OSC 1 Detune 5 Waveform Pulse Pulsewidth 52 Level 70 OSC 2 Detune 5 Waveform Pul...

Страница 12: ... held in the Programmer is dumped to the Pulse The parameter values of the Pulse s current program are overwritten As long as you do not save you perfectly can revert to your original Pulse program Note A request only makes sense if you request the program number you are currently using and playing You can as well request any other program number The problem is the displayed original values of the...

Страница 13: ... to the Pulse immediately Pulse and Programmer are automatically in sync then Note as long as you did not save the Program on the Pulse it resides just in the Pulses edit buffer With BACK you can leave the LOAD page at any time You will find yourself on the 1st page of E Patch Mode then If you press SAVE things look quite similar But now you can give the program to save a name before pressing YES ...

Страница 14: ...value will remain on 1 It comes into play if you want to use multiple Pulses in a cascade to get a polyphonic Pulse See Chapter 10 Cascading for details Change the count of Pulses with 2nd or 3rd encoder In case you ask yourself why the Programmer has to know how much Pulses are connected as soon as the Pulse count exceeds 1 there are 2 things changing in the Programmer Env Trigger screen shows th...

Страница 15: ...Arpeggiator mode set to ON or HOLD This will be recognized by the Programmer on incoming dumps or manual requests You see at any time the current state of the arpeggiator Arpeggiator Setup Now you want to change the Arpeggiator settings Hold one of the 2 buttons for 2 seconds and enter Arpeggiator setup The Programmer s Display will show something like the picture to the right side On entering Set...

Страница 16: ... way and offers poly or unison mode in Env Trigger Display The number of connected Pulses can be set in the Programmer s Preferences Program Management Program changes have to be made on the 1st Pulse only the selected program will be distributed to the Programmer and all connected Pulses automatically A manual Program Request using Sync Mode is technically not possible in the cascade Parameter ch...

Страница 17: ...e 0 LFO2 Speed 64 LFO2 Delay 0 ENV1 Attack 0 ENV1 Decay 32 ENV1 Sustain 0 ENV1 Release 0 ENV1 Track 64 ENV1 Trigger Single1 0 ENV2 Attack 0 ENV2 Decay 0 ENV2 Sustain 127 ENV2 Release 0 ENV2 Track 64 ENV2 Trigger Single1 0 Pitch Mod Amount 0 64 Pitch Mod Source Off 0 Porta Time 0 Porta Mode Normal 0 Pitchbend Scale 12 Mod 1 Source Off 0 Mod 1 Amount 0 64 Mod 1 Destination 0 Pitch Mod 2 Source Off 0...

Страница 18: ...d use SysEx Librarian The technical part Switch off the Stereoping Programmer Connect MIDI OUT of your Midi Interface directly to the jack MIDI 2 IN of the Programmers using a short cable of good quality There are some preferences in most SysEx Dump Programs like Delay between Buffers or Delay after F7 Please choose something around 100mS Milliseconds here Hold MOD and power up your Programmer The...

Страница 19: ...13 Imprint Stereoping is a registered trademark of Gregor Zoll Germany Adresse Gregor Zoll Musikelektronik Hermann Voss Str 21 59872 Meschede Germany E Mail hello stereoping com Homepage http www stereoping com Synth Programmer for Waldorf Pulse Operation manual V 1 0 01 2018 Stereoping Germany Meschede 2018 ...

Страница 20: ......

Отзывы: