background image

5

Operation

• Place the rework station on a flat 

surface, and place the handle on its 

shelf.

• Connect the power cord, fix the nozzle which you need (use the air flux knob 

to 

set the air capacity to max).

• 

Switch the power on, set the temperature which you need using the buttons 

(

/

▲)

.

• 

The unit will heat till it reaches the selected temperature. 

• 

After operation you must put the handle on its shelf. The unit will stop heating 

automatically, and will enter standby state.

• 

Disconnect the power if you don’t use the unit for a long time.

 

Note:

You can make the life span of the heating elements longer and make the IC chip safer 

if 

you do your work at a lower temperature and larger airflow. 

 

Note:

When not using the gun, place it in your base, this will be activated automatically in 

idle mode and avoid overheating when used again remove the gun from its base and 

wait for dial again in the temperature display you chose

.

Содержание CAU-280

Страница 1: ......

Страница 2: ...vor revíselo completamente para estar seguro de cómo utilizar apropiadamente el producto Para apoyo compras y todo lo nuevo que tiene Steren visite nuestro sitio web www steren com La información que se muestra en este manual sirve únicamente como referencia sobre el producto Debido a actualizaciones pueden existir diferencias Por favor consulte nuestra página web www steren com para obtener la ve...

Страница 3: ...dependiente Boquillas adicionales IMPORTANTE No intente abrir el equipo puede ocasionar mal funcionamiento y se anulará la garantía Asegúrese que la punta caliente no toque superficies inflamables su cuerpo o el cable de energía Siempre apague la estación cuando deje de usarla No opere la unidad con las manos mojadas Use la estación en un área ventilada y evite inhalar el humo de la soldadura ya q...

Страница 4: ...a un costado de la base Coloque los dos orificios del soporte de la base y apriete los dos tornillos que extrajo Coloque la pistola sobre su soporte y compruebe si la posición es adecuada 2 CONTROLES CONTROL Botón encendido apagado Perilla de flujo de aire Pistola de aire Aumentar temperatura Disminuir temperatura Pantalla ...

Страница 5: ...go en su plataforma La unidad detendrá automáticamente el calentamiento y entrará en estado de espera Desconecte la alimentación si no va a utilizar la unidad por un largo tiempo PRECAUCIÓN Usted puede extender la vida útil de los elementos de calentamiento y proteger el chip IC si realiza el trabajo a una temperatura inferior y mayor flujo de aire PRECAUCIÓN Cuando no utilice la pistola coloquela...

Страница 6: ...la temperatura subirá o bajará rápidamente Al soltar las teclas la temperatura seleccionada aparecerá durante dos segundos en la ventana de visualización y a continuación aparecerá la temperatura real significa que la temperatura es inferior a 100 ºC y la estación entra en el modo de espera La pistola debe ponerse en su soporte S E significa que el interruptor está encendido pero el conector de la...

Страница 7: ...ués de usar compruebe que la unidad se haya enfriado y colóquela en un lugar seguro No desconecte el enchufe durante este proceso de enfriamiento la pistola se apagará automáticamente un minuto más tarde Durante el funcionamiento la distancia entre la salida y el objeto debe ser al menos 2 mm a partir de la salida de la boquilla Según los requisitos de trabajo elija la boquilla adecuada ya que par...

Страница 8: ...e operación 300 W Potencia máxima 700 W Temperatura de operación 100 C a 450 C Flujo de aire 120 L minuto máximo Ruido 45 dB Consumo nominal 1 8 kWh mes Consumo en espera 132 4 kWh mes El diseño del producto y las especificaciones pueden cambiar sin previo aviso ...

Страница 9: ...nde adquirió el producto Si la presente garantía se extraviara el consumidor puede recurrir a su proveedor para que le expida otra póliza previa presentación de la nota de compra o factura respectiva DATOS DEL DISTRIBUIDOR Nombre del Distribuidor __________________________ Domicilio ______________________________________ Producto ______________________________________ Marca _______________________...

Страница 10: ...1 ...

Страница 11: ...ldering welding station Please review this manual thoroughly to ensure proper installation and operation of this product For support shopping and everything new at Steren visit our website www steren com CAU 280 The instructions of this manual are for reference about the product There may be differences due to updates Please check our website www steren com to obtain the latest version of the inst...

Страница 12: ...ree additional tips for an accurate air flow Adjustable air flow Independent temperature control Additional tips IMPORTANT Do not try to open the device may cause damages and warranty will be void Do not touch the metallic parts near the tip Do not use or store the equipment in wet or damp places It may cause malfunction or shock hazard Turn the power off while taking breaks and when finished usin...

Страница 13: ... Remove the two screws on the side of the base Put the two installation holes of the handle shelf over the fixed screw holes and then screw the two removed screws tightly Put the handle on its shelf and check if it is suitable CONTROL Power on off Air flux knob Hot air gun Temperature up Temperature down Screen ...

Страница 14: ...u must put the handle on its shelf The unit will stop heating automatically and will enter standby state Disconnect the power if you don t use the unit for a long time Note You can make the life span of the heating elements longer and make the IC chip safer if you do your work at a lower temperature and larger airflow Note When not using the gun place it in your base this will be activated automat...

Страница 15: ... is pressed and hold the temperature will rise or lower rapidly If you release the pressed keys the selected temperature will appear for two seconds on the display window and then the actual temperature will appear means the outlet temperature is lower than 100 ºC and the rework station enters the waiting mode The handle should be put on its shelf S E represents the switch turned on but the connec...

Страница 16: ...ut it on the table or other places Keep the blowing way unblocked After using make sure the unit cool down put it in a safe place When operating the distance between the outlet and the object should be at least 2 mm on the basis of the outlet According to the work requirements choose a suitable nozzle for different nozzles there are a little difference in temperature ...

Страница 17: ... 300 W Maximum power output 700 W Operational temperature 100 C to 450 C Air flow 120 L minute maximum Noise 45 dB Nominal consumption 1 8 kWh month Stand by power consumption 132 4 kWh month Product design and specifications are subject to change without notice ...

Страница 18: ...y service at any of the addresses mentioned later THIS WARRANTY IS VOID IN THE NEXT CASES If the product has been damaged by an accident acts of God mishandling leaky batteries failure to follow enclosed instructions improper repair by unauthorized personnel improper safe keeping among others a The consumer can also claim the warranty service in the purchase establishment b If you lose the warrant...