Steradian Technologies, LLC
• Very important Sunband is worn on
head
only - any other location may cause internal wire damage
• Prevent internal wire damage by gently pooling Sunband and cord with gun when storing
• Do not wrap cord around gun, hang gun by Sunband, or drag gun by Sunband - may cause internal wire
damage
• Moisture condensation from rain, snow, or high humidity, can occur inside guns. Place the guns in cool
vented area to dry, or add fan if excess moisture. With extreme cases, call Steradian for further instruction
If your gun is experiencing configuration issues, perform
a Factory Reset to return to original settings:
If your gun shows an
error code
on the display, follow the diagnostic
information — —>
Problems still occurring?
Need parts?
Please email
[email protected]
or call (765) 420-9201
for further instructions
6. The Safety of Infra-Red
Despite the name “lasertag”, Steradian
Technologies does not manufacture
any product which contains a real
X-Series User Guide
"
10
Display
Error
Code
Problem
Solution
E1
Disconnected or
damaged Sunband
Cable
• Verify cable is attached to circuit board inside
Sunband
• Verify cable is attached to circuit board inside
gun
• Move to different lighting location to
determine if problem is light source
• Switch cable, then Sunband with working
one to narrow down location of failure
E2
Gun sensor
malfunction
• Move to different lighting location to
determine if problem is light source
• Inspect 3 sensors for damage
• Replace sensor(s)
E3
Game code CRC
does not match
• Perform a factory reset
E4
Game code is invalid
• Perform a factory reset or load another game
E5
Dataflash error
• Contact Steradian for instruction
r9
r9 stays on display
after
start-up
r = release
9 = version
• Verify trigger or red reload button is not being
depressed when powering on gun
• Verify red reload button for damage
• Contact Steradian for instruction
lo
Battery power is low
• Charge battery
S-7X Factory Reset
1.
Insert power key
2.
Push buttons on both sides of display - hold
3.
Remove power key
4.
Release buttons
5.
Display will read 6, if performed correctly
Eclipse 400X Factory Reset
1. Insert power key
2. Push red reload button and pull trigger - hold
3. Remove power key
4. Release reload and trigger
5. Display will read 6, if performed correctly
Содержание Classic Series
Страница 2: ......
Страница 4: ......
Страница 17: ...Steradian Technologies LLC X Series User Guide 13 Notes ...