Tech Support:
www.steppir.com/support
Tel: 425.891.6134
Page 59
JUMPER INSTALLED
AT FACTORY
NOTE: When wiring the control cable from
the coax switch to the connector junction
box, the red and green wire are not used.
Be sure to trim the red and green wire on
each end of the control cable and tape over
it to avoid potential electrical shorts.
CHAPTER NINE
SECTION 9.2
WIRING THE CONNECTOR JUNCTION BOX (continued)
OPTIONAL
80M DIPOLE WIRING SCHEMATIC
FIG. 9.16
5
4
3
2
1
S
4
3
2
1
W
H
ITE
S
H
IEL
D
DO NOT USE
BL
ACK
DO NOT USE
J2 HEADER
80M DIPOLE
SWITCH BOX
J6 HEADER
80M DIPOLE
SWITCH BOX
REFLECTOR
EHU LUG
DIRECTOR 2
EHU LUG
J6 PLUG
LOCATED INSIDE CONNECTOR
JUNCTION BOX