StepperOnline DM542T Скачать руководство пользователя страница 11

DM542T(V4.0) Digital Stepper Drive User Manual

9

12. Troubleshooting

In the event that your drive doesn’t operate properly, the first step is to identify whether the problem is electrical or
mechanical in nature. The next step is to isolate the system component that is causing the problem. As part of this
process you may have to disconnect the individual components that make up your system and verify that they
operate independently. It is important to document each step in the troubleshooting process. You may need this
documentation to refer back to at a later date, and these details will greatly assist our Technical Support staff in
determining the problem should you need assistance.

Many of the problems that affect motion control systems can be traced to electrical noise, controller software errors,
or mistake in wiring.

Problem

Symptoms and Possible Causes

Symptoms

Possible Problems

Motor is not rotating

No power
Microstep resolution setting is wrong
DIP switch current setting is wrong
Fault condition exists
The drive is disabled

Motor rotates in the wrong direction

Motor phases may be connected in reverse

The drive in fault

DIP switch current setting is wrong
Something wrong with motor coil

Erratic motor motion

Control signal is too weak
Control signal is interfered
Wrong motor connection
Something wrong with motor coil
Current setting is too small, losing steps

Motor stalls during acceleration

Current setting is too small
Motor is undersized for the application
Acceleration is set too high
Power supply voltage too low

Excessive motor and drive heating

Inadequate heat sinking / cooling
Automatic current reduction function not being utilized
Current is set too high

Содержание DM542T

Страница 1: ...ual DM542T V4 0 2 Phase Digital Stepper Drive Revision 4 0 Record of Revisions Revision Date Description of Release 1 0 Dec 2016 Initial Release 4 0 Oct 2020 Add 5V 24V logical voltage selector alarm...

Страница 2: ...l Signal and Output Signal 4 4 1 Control Signal Connection 4 4 2 Fault Output Connection 4 5 Motor Connection 4 6 Power Supply Selection 5 6 1Power Supply Sharing 5 6 2 Selecting Supply Voltage 5 7 DI...

Страница 3: ...hen powered on Optically isolated inputs with 5V or 24V Fault output Over voltage and over current protections 2 Specifications 2 1 Electrical Specifications Parameters DM542T V4 0 Min Typical Max Uni...

Страница 4: ...of DIP switch at OFF position It is recommended to mount the drive vertically to maximize heat sink area Use forced cooling method to cool if necessary 3 Connection Pin Assignments and LED Indication...

Страница 5: ...Connector Pin Details ALM 1 Maximum 30V 100mA output 2 Sinking or sourcing 3 The resistance between ALM and ALM is low impedance as default and will change to high when the drive goes into error prote...

Страница 6: ...5 V first then connect 1K resistor If it is 5V please set the S2 to 5V 4 2 Fault Output Connection When over voltage or over current protection happens DM542T V4 0 red status LED light will blink and...

Страница 7: ...age input When selecting a power supply besides voltage from the power supply power line voltage fluctuation and back EMF voltage generated during motor deceleration needs also to be taken into accoun...

Страница 8: ...tor and drive Therefore output current is generally set to be such that the motor will not overheat for long time operation Since parallel and serial connections of motor coils will significantly chan...

Страница 9: ...d in PUL DIR signal pulse direction signal wires and motor wires should not be tied up together It is better to separate them by at least 10 cm otherwise the disturbing signals generated by motor will...

Страница 10: ...correct direction c t3 Pulse width not less than 2 5 s d t4 Low level width not less than 2 5 s e Duty cycle of Pulse signal is recommend 50 11 Protection Functions To improve reliability the drive in...

Страница 11: ...can be traced to electrical noise controller software errors or mistake in wiring Problem Symptoms and Possible Causes Symptoms Possible Problems Motor is not rotating No power Microstep resolution se...

Отзывы: