Stentofon Turbine Compact Series Скачать руководство пользователя страница 3

2.3 

Audio Settings 

To configure audio settings:

 

Select 

Advanced Alphacom

 > 

Audio 

from the 

menu

Microphone Sensitivity 

 - Select the sensitivity level in the range 0 to 7 from the 

drop-down box. The default setting is 5.

Automatic Volume Control

 - Check box to enable automatic volume control that is 

adjusted according to the noise level

Debug Automatic Volume Control

 - Check box to show current volume level on OLED display

Conversation Mode

 

-

Full Open Duplex

: Normal mode with echo cancellation

 

-

Robust Duplex

: Option used when open duplex fails due 

to excessive speaker loudness, microphone overload or 

very high nonlinear distortions.

 

-

Half Duplex Switching

: Switches speech direction 

depending on who speaks the loudest

 

-

Push-To-Talk

: Half-duplex communication. Initially the 

microphone is shut off. Push the M-button to open the 

microphone, and release to listen. (TCIS-1 station only)

 

-

Open

: Full Open Duplex without echo cancellation

Line Out Source

Plays audio either from VoIP signal (

Speaker

) or direct 

from 

Microphone

.

2.4 

I/O Settings

 

Select 

Advanced AlphaCom

 > 

I/O Settings 

from 

the menu

 

Select either 

Input

 or 

Output

 options from the 

drop-down box for 

I/O Pins

 1 to 6.

2.5  OLED Labels

 

L

Note that only Turbine stations configured with 

OLED Labels 

(TCIS-4, TCIS-5)

  under 

Main  Settings 

will  have  this  menu 

option.

 

 Select 

Advanced AlphaCom

 > 

OLED Labels 

from the menu

OLED Display Text

 

● Enter display text in the relevant fields for OLED 1 

and OLED 2. 

OLED Font Size

 

The font size can be either 

12

 or 

16

OLED Brightness

 

Brightness: 

Default

Bright

Extra Bright

2.6  Address Book

 

L

Note that only the Turbine station configured as a 

Scrolling 

Station (TCIS-6)

  under 

Main  Settings

  will  have  this  menu 

option.

 

Select 

Advanced AlphaCom

 > 

Address Book 

from the menu

Default Display Text

 

The idle text shown in the display may be changed. 

The default text is: 

Scroll to Select

Font Size

 

The font size can be either 

12

 or 

16

OLED Brightness

 

Brightness: 

Default

Bright

Extra Bright

Start Scrolling After

 

Set the time in minutes after which scrolling should 

start

Содержание Turbine Compact Series

Страница 1: ...switching power COM NO NC contacts are provided Max 250VAC 220VDC 2A 60W Input Output 6 general purpose I Os are available Each I O can be configured as either button input or LED driver Audio Line Out A balanced 600 ohm audio line out with induction loop signal 1 2 Power Supply The Turbine Station supports Power over Ethernet PoE IEEE 802 3 a f where power can be drawn from either the spare line ...

Страница 2: ...will be displayed To log into the station 1 Click Login 2 Enter the default User name admin 3 Enter the default password alphaadmin 2 2 Station Main Settings Click Station Main Main Settings to access the page for configuring station mode and IP parameters Station Mode Select the Use Alphacom radio button Turbine Frontboard Depending on the type of Turbine Compact station select one of the options...

Страница 3: ...ation Line Out Source Plays audio either from VoIP signal Speaker or direct from Microphone 2 4 I O Settings Select Advanced AlphaCom I O Settings from the menu Select either Input or Output options from the drop down box for I O Pins 1 to 6 2 5 OLED Labels L L Note that only Turbine stations configured with OLED Labels TCIS 4 TCIS 5 under Main Settings will have this menu option Select Advanced A...

Страница 4: ...valid IP address No gateway or wrong gateway to the AlphaCom server exchange Talk Icon Flashing at 5 second intervals Station connected but NOT registered in the AlphaCom server exchange Reason Station has not been programmed in AlphaPro 4 Restoring Default Settings 4 1 Reset to Default with Activated DHCP To reset 1 While pressing any button power up the station by connecting to a PoE switch 2 Ho...

Отзывы: