19
Pro700
Installation and Programming Manual
A100K10226 v.4.1 Jul. 2006
Handset
GD745
An external Handset Module can be connected to perform low-
speaking conversations.
;
Connect all wires from the handset module GD745 to the
TB3
screw terminal block:
- Microphone
1 - 3
- Ear capsule
2 - 3
- Cradle switch
4 - 6
- T-button
5 - 6
10 Watt amplifier
FC740
A10 W Amplifier Module can be mounted inside the stations
according to separate instructions.
;
Connect external loudspeaker(s) to
TB4
terminals
1
and
2
.
;
Connect external 24 Volt DC or AC to
TB4
terminals
3
and
4
- positive pole to terminal
3
.
5.4 AA706, AB731, AB731-F, AB731A, AB731A-F
The 3-pair installation cable is connected to terminals
1 - 4
and
7 - 8
on screw terminal block
TB1
on the printed circuit board NFE1825.
Extra equipment is connected to terminals 5/6 and 9/10 on terminal
block
TB1
and to
TB2
on NFE1829.
The stations have to be opened to get access to the terminal blocks.
External loudspeaker
;
Connect a 20 – 50 ohm loudspeaker to terminals
TB1 - 5
and
6.
-
The loudspeaker can be connected independent of other
equipment.
Remote Output
The built-in relay can carry max. 5 A.
Door opening:
(activated by "5" from a priority station during
conversation).
;
Connect the door magnet in series with its power supply to
terminals
TB1 - 9
and
10
.
Remote Input, Emergency Call
External switch in parallel with the keyboard switch "9".
;
Connect a closing contact switch to
TB2
terminals
1
and
2
.
Local Reset
Reset a CAS call-in station by pushing an external switch “X”.
;
Connect a closing contact switch to
TB2
terminals
3
and
4
.
Local Output
A lamp will light when a CAS call-in or doorbell call is made.
;
Connect a max. 5 W lamp to
TB2
terminals
5
and
6
.
-
The lamp voltage must correspond to the available power!
1
2
3
4
5
6
TB3
Ear
GND
Mic
Cradle
PTT
Common
T
1
2
3
4
TB4
24VAC/DC
+
POW
10W
1
2
3
4
5
6
7
8
9
10
TB1
24V
+
-
Signal
Signal
Power +
Power -
Program
Program
1
2
3
4
5
6
7
8
9
10
5A
TB1
1
2
3
4
5
6
TB2
12-24V
5W
ALARM
RESET CAS
“X”
“9”