5 CONNECTING
STATIONS
5.1 AA711
Open the lid on the rear of the station to get access to the
programming DIP switches and strap jumpers.
z
The station cords BF640/641/642/ 643 are used to terminate this
station to an 8-pin modular jack wall socket, KB170 or KB171.
Note that some types of wall sockets on the market do not always
have the same connection layout.
z
The 3-pair installation cable is connected to the terminals 2-7in the
wall socket as shown
z
Jumper
A
and
B
must be set to allow program distribution.
z
Pin 1 and 8 are reserved for optional external loudspeaker or
remote output.
External loudspeaker
;
Set jumper
F
and
G
in
pos
1 - 2
.
;
Connect a 20 ohm loudspeaker to terminals
1
and
8
.
Remote Output
The built-in relay can carry max. 48 V/1 A.
;
Set jumper
F
and
G
in
pos
2 - 3
.
;
Connect the optional equipment in series with its power supply to
terminals
1
and
8
.
Door opening:
(activated by "5" from a priority station during
conversation).
;
Set jumper
E
pos
1 - 2
.
Optional Warning:
(active when station is called, cancelled by "2").
;
Set jumper
E
pos
2 - 3
.
External call switch
Program distribution can be substituted by an external switch in
parallel with the keyboard switch "6"
or
"9".
;
Connect the switch between terminals
2
and
6
.
;
Remove jumper
A
and
B
Silent Alarm, button 6:
;
Set jumper
C.
Emergency call, button 9:
;
Set jumper
D
.
Note that the program distribution cable
must not
be connected to
terminals 2 and 7 if an external switch is used.
5.2 AA702, AB708 and AB709
The 3-pair installation cable is connected to the terminal block on the
back plate of these stations.
The stations have to be opened to get access to the terminal block.
1
2
3
4
5
6
7
8
24V
+
-
8
1
RJ
4
5
front vie w
E
1 2 3
G
F
B C D
A
Program
Power +
Signal
Signal
Power -
Program
Wall socke t
Default stra p se tting
1
2
3
4
5
6
7
8
24V
+
-
Program
Power +
Signal
Signal
Power -
Program
1 A
1
2
3
4
5
6
7
8
E
E
E
1 2 3
1 2 3
1 2 3
G
G
G
F
F
F
EXT
B C D
A
B C D
A
“6”
“9”
Ext. LS
Door
Opt.
warn.