STENTOFON and VINGTOR products are developed and marketed by Zenitel Norway AS. The company’s Quality Assurance System is certified to meet the requirements in NS-EN ISO 9001:2008. Zenitel Norway AS
reserves the right to modify designs and alter specifications without prior notice, in pursuance of a policy of continuous improvement. © 2011 Zenitel Norway AS.
DOC NO.
A100K11061
To log into the substation:
1. Click
Login
2. Enter the default User name:
admin
3. Enter the default password:
alphaadmin
The
Station Information
page will now be displayed,
showing the IP substation configuration.
2.2
Station Main Settings
●
Click
Station Main
>
Main Settings
to access
the page for configuring station mode and IP
parameters.
Registration Settings
●
Enter the IP address of the AlphaCom server/
exchange in which the IP substation is to be a
subscriber in the
AlphaCom IP-address
field.
●
Enter the directory number of the substation in the
Directory Number
field.
- If a directory number is not entered, the substation
will register with its MAC address. The MAC address
is found on the Station Info page and needs to be
entered into the AlphaPro programming tool.
IP Settings
●
DHCP
– Use this option if the IP substation shall
receive IP Settings from a DHCP server.
●
Static IP
– Select this option if the IP station shall
use a static IP address. Enter values for:
-
IP-address
-
Subnet-mask
-
Gateway
●
Click
Save
followed by
Apply
to apply the new
configuration settings.
3
Restoring Default Settings
An IP Substation may have to be reset to its original
factory default settings if, for instance, the password to
the web server is forgotten. The defaults can be either
be set to Static IP or Activated DHCP (when there are
many new IP Substations in an installation).
3.1
Reset to Default Settings with Static IP
1. While pressing the call button, power up the
substation.
2. When the substation LED starts blinking, release
the call button
after exactly 1 blink
.
3. Let the LED blink for
exactly 2 more times
, then
press the button again.
4. Keep the button pressed until the LED
blinks fast 2
times
indicating a successful reset with static IP.
5. Release the button and the substation will restart
with the factory default settings.
Factory default values
- Station IP address:
169.254.1.100
- AlphaCom IP address:
169.254.1.5
- Username:
admin
- Password:
alphaadmin
3.2
Reset to Default Settings with Activated
DHCP
1. While pressing the call button, power up the
substation.
2. When the substation LED starts blinking, release
the call button
after exactly 2 blinks
.
3. Let the LED blink for
exactly 4 more times
, then
press the button again.
4. Keep the button pressed until the LED
blinks fast
4 times
indicating a successful reset with activated
DHCP.
5. Release the button and the substation will restart
with the factory default settings.
Factory default values
- Station IP address:
determined by DHCP server
- AlphaCom IP address:
169.254.1.5
- Username:
admin
- Password:
alphaadmin
14.12.2011