Getting Started
IP Substations
The information in this document pertains to the
following STENTOFON IP Substations:
Vandal Resistant
IP Substation
Vandal Resistant
IP Substation (3 Gang)
1
Installation
The table below is an overview of the main connectors
involved when installing the IP Substations.
LAN
10/100 Mbps RJ45 port for LAN (uplink) connection.
Supports PoE (802.3af). Draws power from either spare
line or signal line.
AUX
10/100 Mbps RJ45 ports for auxiliary equipment such as
PC and IP camera.
Input/Output
Pluggable screw terminal
Local Power
Pluggable screw terminal, 19-27 VDC Idle 4W, max. 8W
1.1 Power Supply
The IP Substation supports Power over Ethernet (PoE,
IEEE 802.3 a-f) where power can be drawn from either
the spare line or signal line. If PoE is not available,
the IP Substation can be connected to a local 24 VDC
power supply.
1.2 Network Connection
There are two RJ45 ports on the IP Substation:
●
LAN port is for connecting to the network and the
AlphaCom server/exchange.
●
AUX port is for connecting to auxiliary equipment
such as a PC.
RJ45 Ports on IP Substation PCB
2
Configuration
A web browser is used for the configuration of the IP
Substation.
For substation configuration, there are essentially three
parameters to set:
●
AlphaCom IP address
●
Station directory number
●
Station IP address
2.1 IP Substation Web Interface
The IP Substation features an embedded web server,
which allows users to log in via a standard web
browser. At commissioning, the IP substation needs to
be configured to enable it to subscribe to an AlphaCom
server/exchange. To do this, your PC and the IP
substation have to be connected together via a PoE
switch using network cables:
●
Connect the PC to the PoE switch
●
Connect the LAN port on the IP substation to the
PoE switch
The factory default IP address of the substation is
169.254.1.100
. In order for your PC to communicate
with the substation it is necessary to change its
Internet Protocol Properties
to use an IP address
that is in the same range as 169.254.1.100, e.g.
169.254.1.1 with subnet mask 255.255.255.0.
After the IP properties have been changed, access the
substation by logging into the web interface using a
standard web browser:
1. Open a web browser
2. In the browser’s address bar, type the default IP
address
169.254.1.100
and press the ENTER key
- The substation login page will be displayed.
LS
LE
D
K
EY
1
K
EY
2
K
EY
3
R
EL
AY
0V
E
XT
24
V E
XT
+
STATUS
Green/Red LED
STATION
LED
AUDIO OUT
600
Ω
Communication
LED
Ethernet speed
LED
LAN
AUX
P3
P4
C
A
TP1
TP2
1
1
6
6
TP9