20
-
-
20
-
ACTIVATING OR DEACTIVATING OPEN WINDOW DETECTION
By default, the thermostat will detect if a window is open in the room where it is located, and the thermostat automatically
adjusts the set temperature to 7 °C (45 °F) to avoid heating the room unnecessarily.
1 -
Access menu 5.
2 -
Use the
and
buttons to activate (ON) or deactivate (OFF) open window detection.
3 -
Touch the
button to confirm the selection.
ACTIVATING OR DEACTIVATED PROXIMITY DETECTION
By default, the thermostat screen automatically turns on when it detects a presence nearby. You can deactivate this feature,
to prevent the thermostat from turning on every time you enter a child's room, for example. When this feature is deactivated,
simply touch one of the thermostat buttons to turn on the screen.
1 -
Access menu 6.
2 -
Use the
and
buttons to activate (ON) or deactivate (OFF) proximity detection.
3 -
Touch the
button to confirm the selection.
RESETTING THE THERMOSTAT
You can reset the thermostat to restore its default settings.
1 -
Access the Reset menu (DEF).
2 -
Use the
and
buttons to select "Y" and revert
to default values.
3 -
Touch the
button to confirm the reset.
The thermostat may take a few seconds to reset.
ALL PARAMETERS RETURN TO THEIR DEFAULT
VALUE AND THE CONNECTION TO THE ZIGBEE
NETWORK AND THE CONTROLLER
•
THERMOSTAT
IS DELETED. THE CONTROLLER
•
THERMOSTAT STILL
DISPLAYS THE THERMOSTAT, EVEN IF IT CAN NO
LONGER CHECK IT. THEREFORE, YOU MUST DELETE
THE CONTROLLER
•
THERMOSTAT MANUALLY
(SEE THE MAESTRO CONTROLLER
•
THERMOSTAT
INSTALLATION AND USER GUIDE).
IMPORTANT