Installation, Operation and Maintenance (IOM) Manual 

Extreme hazard which will 

result of severe injury or 

death 

Hazard which could result 

of personal injury or 

severe damage to 

property 

Hazard which could result 

of minor injury or damage 

to property 

 
TABLE OF CONTENTS: 
 

Section I: Introduction 

 

 

------------------------------------------------------------------------------ Page 3 

 

 

Section II: General Practice  

 

------------------------------------------------------------------------------ Page 4 

 

 

Section III: Warranty 

 

 

------------------------------------------------------------------------------ Page 4 

 
Section IV: Storage  

 

 

------------------------------------------------------------------------------ Page 4 

 

 

Section V: Installation 

 

 

------------------------------------------------------------------------------ Page 5 

 
Section VI: Operation Procedure 

 

------------------------------------------------------------------------------ Page 6 

 
Section VII: Maintenance Procedure 

------------------------------------------------------------------------------ Page 7 

 
Section VIII: Spare Parts   

 

------------------------------------------------------------------------------ Page 8 

 
Section IX: Exploded View  

 

------------------------------------------------------------------------------ Page 8 

 
Section X: Trouble Shooting 

 

------------------------------------------------------------------------------ Page 9 

 
 

 
SECTION I: INTRODUCTION  

 
STELLAR BDS Series submersible borehole stainless steel pumps are designed for extreme high in head. The said 
series is made in stainless steel with built-in non return valve.  Cost economical, space saving, high quality & wide 
series  of  applications  in  deep  wells,  thermal  well,  reservoir,  canals  &  irrigations.  It  can be  used  in  commercial 
establishments, industrial sectors, municipal & water districts. 
 
This IOM Manual shall be read entirely prior for installation and operation. Stellar Pump shall not be liable for 
any injuries, damages & pertaining cost due to failure in observing the instructions and maintenance contained 
in this manual.  
 
The following symbols indicated in this manual are needed to pay attention: 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

Содержание BDS Series

Страница 1: ...Stellar Pump Australia 1 Installation Operation and Maintenance IOM Manual Installation Operation Maintenance Manual BDS Series Submersible Borehole Stainless Steel Pump...

Страница 2: ...umbers are not on the list it means The list is not yet updated quarterly updating the Authentic page It has been removed to accommodate newly registered serial numbers The product s that you have rec...

Страница 3: ...View Page 8 Section X Trouble Shooting Page 9 SECTION I INTRODUCTION STELLAR BDS Series submersible borehole stainless steel pumps are designed for extreme high in head The said series is made in sta...

Страница 4: ...before performing installation operation and maintenance of this pump SECTION III WARRANTY CONDITION This warranty applies against all defective materials and or faulty manufacture for the period of...

Страница 5: ...h necessary codes b Water tanks must be free from any constructions debris large solid particles or welding fluxes to avoid damaging the internal parts of the pump c Submersible pump may be installed...

Страница 6: ...heck water source Never operate the pump if water has presence of excess sand or any solid particles d Check motor insulation using insulation tester Never activate the motor if insulation reading is...

Страница 7: ...e within the normal range Compare the said readings with previous data d Water level in deep well or water tank should be sufficient enough while pump is operation e Check quality of water discharging...

Страница 8: ...y Item Description 5 Impeller 11 Strap Refer to Section IX for reference b Continuous operation Item Description 5 Impeller 11 Strap 7 Diffuser Chamber 8 Valve Cap 6 Bearing 4 Seal ring SECTION IX EXP...

Страница 9: ...d wires cables to reverse the rotation 5 Replace impeller but take note BHP vs motor HP 6 Remove solid particles 7 Replace wear ring Excessive noise and vibration 1 Trap air or leak at main riser colu...