Safety Guidelines and Procedures 

Listed below are extremely important safety guidelines that are to be followed 

when installing your Stellar Labs® antenna. Not following these guidelines can 

result in death or serious injury. 

 

Locate and take actions to avoid power lines and other wires in your work space. 

 

Do not climb onto a slick, icy, or wet roof. 

 

Avoid installations in high areas on windy days.  

 

Inspect the ladder you plan on using to ensure it is in safe operable condition.  

 

Do not position your ladder at an angle steeper than 70˚.  

 

Do not climb on roofs that have curled or worn shingles. (Old shingles break easily 
or pull out.)  

 

Wear season-appropriate attire that is neither too loose or too tight. Always wear 
rubber-soled shoes with good grip. 

 

Wear a pair of durable gloves that also allow normal mobility of your hands. 

 

Look around your work area to observe for any potential dangers. 

 

Never climb onto a high location while alone.  

 

Avoid installing your antenna underneath tree braches or other overhanging objects. 

 

Antennas should be installed away from power lines and other wires a distance equal 
to at least two times the  combined length of the mast and antenna.  

 

Grounding Procedure 

Mast Grounding 

The NEC mandates that the antenna mast and mount be grounded directly. There can be no 
splices or connections in the ground wire between the mast and the grounding rod. First, 

attach one end of a No. 8 or No. 10 copper ground wire to the antenna mast. One of the 
bolts on the antenna mount can be used as a connection point. Masts that are  painted or 

coated can have their coating scraped off on the area where they make contact to the 
mount. This will ensure a proper connection between the mast and the mount. Next, run the 

ground wire to the ground as directly as possible. Wire staples can be used to secure the 
ground wire against the side of a building. Avoid making right angle or sharper turns with 

the ground wire. Lightning has difficulty making such a turn and therefore may discharge 
into the building. Make ground wire turns as smooth and as slight as possible. The ground 

wire must be connected to a grounding rod.  Water faucets and/or pipes are not acceptable. 
A copper-coated steel ground rod driven at least three feet into the ground is required. Spe-
cial clamps that provide a solid connection between the ground wire and grounding rod 

should be used. 

Grounding the Signal Cable 

TV Antennas and signal cable can accumulate static electrical charges that also increases the 
chances of lightning strike. To properly dissipate this static electricity, a grounding block 

should be used. The grounding block is connected to the signal cable at a point close to 
where the signal cable enters the building (a signal splitter that has a tab for ground on it 
will also work.) One end of a ground wire is attached to the grounding block. The other end 

of the wire is connected directly to the grounding rod. An antenna installation is not properly 
grounded unless both a mast ground and an grounding block are installed correctly. 

MCM Part #: 30-2370 

MCMelectronics.com 

This product carries a limited 90 day warranty, which does not   apply if the 

product has been damaged, deteriorates, malfunctions or fails from:     

improper installation, misuse, abuse, neglect, accident, tampering,       

modification of the product as originally manufactured by Stellar Labs® in 

any manner whatsoever, usage not aligned with product instructions or 

acts of nature such as  damage caused by wind, lightning, ice or corrosive 

environments such as salt spray and acid rain. This Limited Warranty also 

does not apply if the product becomes unable to perform its' intended  

function in any way as a result of the television signal provider  making any 

changes in technology or service. Should a failure be determined covered 

by the warranty, it will be the sole discretion of MCM Electronics to repair or 

replace the product.  This warranty covers the product only, and does not 

include any additional product or expense incurred.  No liability outside the 

product itself is implied.  

 

 
 

RETURN AUTHORIZATION POLICY 

A Return Material Authorization (RMA) is required prior to returning any 

product to Stellar Labs® under this warranty policy. Please call our       

Customer Service at (877) 626-3532 or send an email to                      

[email protected] to obtain an RMA number. Enclose 

the product in a prepaid package and write the RMA number in large, clear 

numbers on the outside of the package. To avoid confusion or              

misunderstanding, a shipment(s) without an RMA number(s) or an        

unauthorized return(s) will be refused and returned to Customer freight 

collect.  

Warranty Information 

Отзывы: