Stellar Hearth IGL26 Скачать руководство пользователя страница 1

IMPORTANT: To comply with certifica-
tion, listings, and building code accep-
tance, and for safe operation and proper 
performance, ONLY STELLAR HEARTH 
parts and accessories may be used with 
this gas log set. 

WARNING 

 

Installation and Operation Manual—Models IGL26 & IGL26-LP 

Stellar Hearth Products, a brand of Big Woods Hearth Products         

INS_IGL26_A 

Do not store or use gasoline of other flam-
mable vapors and liquids in the vicinity of 
this or any other appliance. 
 

WHAT TO DO IF YOU SMELL GAS: 



Open a window. 



Do not try to light appliance. 



Do not touch any electrical switch; do not 
use any phone in your building. 



Immediately call you gas supplier from a 
neighbor’s phone.  Follow the gas sup-
plier’s instructions. 



If you cannot reach your gas supplier, call 
the fire department. 

 

Installation and service must be per-
formed by qualified installer, service 
agency or the gas supplier. 

 
 
 
If the information in this manual is not         
followed exactly, a fire or explosion may re-
sult causing property damage, personal in-
jury or loss of  life.  

This gas log set is to be installed only in a 
solid-fuel burning fireplace with a working 
flue constructed of non-combustible material.  
Solid fuels shall not be burned in a fireplace 
where this gas log set in installed.  The in-
stallation, including provisions for combus-
tion, ventilation air, and required minimum 
permanent vent opening, must conform with 
the 

National Fuel Gas Code (Z223.1) 

and 

applicable local building codes.  A damper 
stop clamp is included to maintain the mini-
mum permanent vent opening and to prevent 
full closure of the damper blade.              

The chimney damper should be fully 
opened when burning the log set.  The 
log set is designed to burn with yellow 
flames; thus adequate ventilation is abso-
lutely necessary.  

IMPORTANT: Read these instructions 
thoroughly before starting installation of 
the gas log set. 

 

 

IMPORTANT :  Installer & Homeowner, 

these instructions must be retained with 
this appliance for future reference. 

The Images Gas Log Set can be used in a wood burning masonry or zero-clearance (pre-manufactured) fireplace, 
with or without glass doors

.  

 

NOTE: It is recommended that glass doors be used in conjunction with this unit to maximize your efficiencies.  

 NOTE: We recommend that you check with your local building code official be-
fore you begin installation to ensure compliance with local codes, including the 
need for permits and follow-up inspections.  

Содержание IGL26

Страница 1: ...with a working flue constructed of non combustible material Solid fuels shall not be burned in a fireplace where this gas log set in installed The in stallation including provisions for combus tion ve...

Страница 2: ...ding your fireplace can be found on the rating plate located behind the grate in the valve control area Once you have located the rating plate record the following information and keep with your recor...

Страница 3: ...ss Log Set and Firebox Liner Installation 8 13 A Optional Fireplace Liner Installation 8 B Burner and Log Placement Chart 9 Glass Log Set 1 9 Glass Log Set 2 10 Glass Log Set 3 10 Glass Media 11 Front...

Страница 4: ...red due to excessive lint from carpeting etc It is imperative that control compartments burners and circulating air pas sageways be kept clean 5 A damper clamp must be installed to provide the minimum...

Страница 5: ...Stellar Hearth Products Minimum firebox dimensions needed are Front Width 31 Back Width 19 Depth 15 Height 17 3 SPECIFICATIONS Page 5 3A Minimum Firebox Dimensions 3B Insert Dimensions Figure 3B 1...

Страница 6: ...hen glass fireplace doors are used operate the gas log set with the doors open 4 FIREPLACE REQUIREMENTS Page 6 This log set is designed to be used only in a functioning fireplace that is designed and...

Страница 7: ...nto the firebox 1 Place the chassis as far back in the firebox as possible and center it right to left with the open end facing out ward 2 Locate the flexible gas line on the backside of the insert ch...

Страница 8: ...sis This groove will hold the glass off the fireplace hearth and allow for the flexible gas line route Place the side walls into the side support brackets Page 8 Side Panels Qty 2 Back Panel Qty 1 7 G...

Страница 9: ...Log Placement Glass Set 1 Log 1 Log 6 Step 1 Set 1 Logs 1 6 Insert Log 1 into the slot on the back right side of the chassis with the cutout over the burner tube Insert Log 6 into the slot on the back...

Страница 10: ...r the burner tube Insert Log 5 into the slot on the middle left side of the chassis Figure 7B 3 Also use Figure 7B 1 for reference Glass Set 3 Log 3 Log 4 Step 3 Locate Set 3 Logs 3 4 Insert Log 3 int...

Страница 11: ...formed piece of sheetmetal is to keep the beads off the pilot and off a 1 portion of the burner Any remaining beads can be placed behind Logs 1 6 Step 5 Attach Front Grille Remove the front grille fr...

Страница 12: ...e wide end of Log 11 rests into the slot on the top of Log 1 Figure 7B 7 Also use Figure 7B 1 for reference 10 11 Glass Set 5 Log 7 Log 8 Step 7 Locate Set 5 Logs 7 8 Place Log 7 on top of Log 6 and L...

Страница 13: ...uge to connect the log set to an electrical outlet 2 Plug in to the nearest outlet 3 If desired additional glass beads can be purchased through your Stellar Hearth dealer 4 The insert is now ready for...

Страница 14: ...ONLY WHEN THE PRODUCT HAS COOLED DOWN TO ROOM TEMPERATURE 9 OPERATING INSTRUCTIONS 1 With the gas supply turned on simply locate the on off switch in the left hand side of the front grille Turn the sw...

Страница 15: ...gle layer and around the perimeter of the chassis on the firebox floor Check to ensure that the beads are not piled higher on the burner area and that they are not covering the pilot assembly Failure...

Страница 16: ...ore than one layer deep Uneven flame distribution Check to ensure that the glass logs are in their correct and upright position and that the glass beads do not cover the burner ports Rearrange the bea...

Страница 17: ...2 Glass Log 2 IGL 3 Glass Log 3 IGL 4 Glass Log 4 IGL 5 Glass Log 5 IGL 6 Glass Log 6 IGL 7 Glass Log 7 IGL 8 Glass Log 8 IGL 9 Glass Log 9 IGL 10 Glass Log 10 IGL 11 Glass Log 11 Red Glass Lens IGL...

Страница 18: ...ducts Inc within 30 days from the date of purchase 6 Pick up and delivery This major appliance is intended to be repaired in your home 7 Repairs to parts or systems resulting from unauthorized modific...

Отзывы: