background image

 8

SET BUTTON  

4

The range can be displayed either in meters or in yards, as 
desired. After pressing the button for distance measuring 

 

3

 

a ‘m’ for meter or ‘y’ for yards is displayed next to the target 
marker. 
To change the setting, use the SET button 

 

4

 : An extended 

press of the button for over 3 seconds will cause the display to 
start to fl ash and the setting to then change every time the SET 
button is pressed. 
All settings preset for the ‘m’ represent range displays in 
meters; all settings preset for the ‘y’ represent range displays 
in yards. The selection of setting ‘m’ (display in metres) or 
‘y’ (display in yards) is preferable for the basic use. After 5 
seconds without pressing the SET button the respective setting 
is saved automatically.

SCAN MODE

The STEINER Military 10x50 Laser rangefi nder binocular can 
also be used to measure in constant operation (scan mode). 
The scan mode is particularly helpful for measuring small or 
moving targets. 
If the button for measuring distance 

 

3

 is pressed for longer 

than approx. 3 seconds, the binocular switches to scan mode 
and then takes measurements continuously. This can then be 
identifi ed from the range display which emits new measuring 
values approx. every 1.5 seconds.

Note:

 Scan mode consumes more power than individual 

metering due to the constant metering. Scan mode switches 
off automatically after approx. 20 seconds in order to save the 
battery in case the button is pressed accidentally.

DISTANCE MEASURING

Содержание M1050r LRF

Страница 1: ...English INSTRUCTION INSTRUCTION MANUAL MANUAL ...

Страница 2: ... with household waste Please use any existing return system in your local area when returning used batteries Please only hand in discharged batteries Batteries are generally discharged when the equipment operated with them switches off or indicates battery empty the battery no longer functions correctly after an extended period in use To prevent short circuits cover the battery contacts with an ad...

Страница 3: ...AFETY Disposal of electronical equipment Battery disposal Important notice for USA IDENTIFICATION OF THE COMPONENTS INSERTING AND CHANGING THE BATTERY Battery charge level RANGE ESTIMATION ACCURACY DISTANCE MEASURING Scan Mode CLEANING CAUTION TECHNICAL SPECIFICATIONS NOTES ...

Страница 4: ...4 1 3 4 5 6 2 IDENTIFICATION OF THE COMPONENTS 1 Eyepiece with rubber eyecup 2 Diopter adjustment 3 Power Measure button 4 Set button 5 Laser transmission optics 6 Battery compartment ...

Страница 5: ...he battery cover back on by turning clockwise BATTERY CHARGE LEVEL A new battery is sufficient for more than 5 000 measurements at 20 C Depending on the conditions of use the battery life time can be significantly shorter or longer than this Low tem peratures and frequent use of the scan mode shortens the battery life A flat battery is indicated by a flashing measured value and target display Warn...

Страница 6: ...ith sunshine and good visibility the ranges and accuracies are as follows Measuring range 20m 22yds up to 1500m 1600yds Accuracy 1m yd up to 350m 380yds 2m yds up to 700m 763yds 0 5 above 700m 763yds RANGE ESTIMATION ACCURACY Range higher lower Color of object white black Angle to object vertical acute Size of object large small General brightness low cloudy high midday sun Atmospheric conditions ...

Страница 7: ...ion of the target will go off shortly during the measurement You can start a new measurement at any time by pressing the button for distance measuring 3 again If the object distance is less than 20 meters 22yards or if the range is exceeded or the object does not reflect sufficient light the display shows When the display turns off the distance meter is automatically deactivated Note Depending on ...

Страница 8: ... the basic use After 5 seconds without pressing the SET button the respective setting is saved automatically SCAN MODE The STEINER Military 10x50 Laser rangefinder binocular can also be used to measure in constant operation scan mode The scan mode is particularly helpful for measuring small or moving targets If the button for measuring distance 3 is pressed for longer than approx 3 seconds the bin...

Страница 9: ...ry rubbing may scratch the lens surface and eventually cause permanent damage For more thorough cleaning use a lens cleaning fluid Always apply the fluid to the cleaning cloth never directly on the lenses CAUTION When using the binoculars never point directly at the sun The heat generated by the focused rays of the sun may be very harmful and might cause serious damage to your eyes permanently ...

Страница 10: ...bar Ocular individual adjustment Weight approx Binocular 1 270 g Carrying strap 55g Objective caps 42 g Eyepiece cover 17 g Dimensions approx Height 137 mm Width 207 mm Depth 100 mm Measuring range 20m 22yds up to 1 500m 1 600yds Accuracy 1m yd up to 350m 380yds 2m yds up to 700m 763yds 0 5 above 700m 763yds Laser eyesafe invisible laser according to EN and FDA class 1 Figures correspond to an ocu...

Страница 11: ...11 NOTES ...

Страница 12: ...Item Number V0000229 2020 05 STEINER OPTIK GmbH Dr Hans Frisch Str 9 95448 Bayreuth GERMANY Phone 49 921 7879 0 military steiner de www steiner defense com ...

Отзывы: