Table 4-1 Preventive Maintenance Checks and Services
Malfunction
Test / Inspection
Corrective Action
Ref. Para.
1. POINT/ILLUM
e. Inspect battery contact spring
-Notify Unit Maintenance.
beams fail to come
in the battery compartment for
on or stay on.
damage or corrosion.
f. Possible internal failure.
-Notify Unit Maintenance.
2. POINT/ILLUM
a. Verify Exit Port Cover is
-Remove Exit Port Cover. 4.3.b
beams have
removed and that Exit Port Lens -Clean POINT & ILLUM
become weak
is not obscured by mud / dirt.
Exit Port Lenses.
(not as bright).
b. Verify proper battery installation. -Tighten battery cap.
3.2.a
-Install new battery.
--
c. Verify Exit Port Lens is not
-Notify Unit Maintenance.
scratched or pitted.
3. POINT/ILLUM
a. Verify adjuster function.
-Clean as required.
4.3.a
beams DO NOT
-Notify Unit Maintenance.
move.
4. Remote Cable
a. Verify Remote Cable Switch
-Reconnect plug.
3.2.e
Switch inoperable,
plug is fully seated.
but Integrated
Momentary
Activation Switch
functions.
b. Verify Remote Cable Port is
-Flush with water.
4.3.g
free of mud / dirt.
c. Inspect Remote Cable Plug
-Clean as needed.
Contacts.
d. Verify function of Remote Cable -Notify Unit Maintenance.
Switch.
62
Содержание DBAL-I2
Страница 1: ...DUAL BEAM AIMING LASER VISIBLE LASER POINTER IR LASER Technical Manual ...
Страница 9: ...CHAPTER 1 GENERAL INFORMATION 8 Figure 1 1 DBAL I2 in Use ...
Страница 51: ...Figure 3 14 Laser Borelight 10 meter Zeroing Target 50 ...
Страница 55: ...Figure 3 15 Commercial 25 meter Zeroing Target 54 ...
Страница 78: ...77 APPENDIX A REPAIR PARTS Figure 1 Repair Parts ...