3. Stabilize the weapon so it does not move and insert the Borelight Arbor
assembly into the muzzle of the weapon.
4. Activate the Borelight and verify that the Borelight is properly aligned. Refer
to LBS Operator’s Manual for zeroing procedures.
5. Adjust the target as required to place the laser dot on the target location
marked “Laser Borelight.”
6. Activate the IR POINT by rotating the Activation Mode Selector Switch to the
AIM LO (A/L) position. Adjust the Aiming Laser windage and elevation
adjusters until the point is centered on the corresponding offset location.
7. A positive load is required on the adjustment mechanism when zeroing the
DBAL-I
2
for purposes of retaining the set alignment. See Paragraph 3.4.
8. The DBAL-I
2
weapon combination is now boresighted. Rotate the DBAL-I
2
Activation Mode Selector Switch to OFF and remove the Borelight Mandrel
Interface assembly from the weapon. Check the weapon barrel to make sure
it is free and clear.
Repeat above steps to boresight the ILLUM beam.