The shrouds can then be
suspended in the upper
notch in the middle of the
lens and finally fixed in
place by applying the
decorative cover. 

(Refer below: examples
concerning reduction of
angle of coverage and
reduction of reach.)

The shrouds can be sepa-
rated along the pre-groov-
ed divisions in the vertical
or horizontal direction or
cut with scissors. 

Individual fine adjustment with shrouds

Examples

In order to exclude add-
itional areas such as paths
or neighbouring property or

to monitor these specifical-
ly, the detection zone can
be adjusted precisely 

by means of shrouds.

The sensor lens is divided
into two detection zones.
With one half, a max. reach
of 5 m is achieved and with
the other a max. reach of 
12 m (for an installation
height of approx. 2 m). 
After fitting the lens (press
lens firmly into the channel
provided) you will see the
max. reach setting (12 m or
5 m) at the bottom right. 

The lens can be released
laterally from the catch with
a screwdriver and reinserted
according to the desired
reach.

Examples

Reach – basic settings

16

17

Serie_180_10spr.qxd  18.10.2004  15:50 Uhr  Seite 17

Содержание Serie IS 180

Страница 1: ...g Operating instructions Mode d emploi Gebruiksaanwijzing Istruzioni per l uso Instrucciones de montaje Bruksanvisning Brugsanvisning Käyttöohje Bruksanvisning 7216602 Technische Änderungen vorbehalten Service Serie_180_10spr qxd 18 10 2004 15 50 Uhr Seite 1 ...

Страница 2: ...f 180 with an opening angle of 90 is achieved The lens is removable and can be rotated This allows two basic reach settings of max 5 m or 12 m The infrared sensor can be installed without difficulty on inside and outside cor ners using the enclosed wall mounts Dimensions H x W x D 120 x 76 x 56 mm Output max 1000 W ohmic load e g filament bulb max 1500 W uncorrected inductive cos ϕ 0 5 e g fluores...

Страница 3: ...of 5 12 m the installation height should be approx 2 m Installation steps 1 Remove decorative cover 2 Release catch and fold up lower half of housing 3 Mark drilling holes 4 Drill the holes and insert plugs 6 mm dia 5 Prepare wall according to needs for flush or sur face mounted wiring 6 Wire up the supply and service leads and connect Use sealing plugs for sur face mounted wiring a Connection of ...

Страница 4: ...s paths or neighbouring property or to monitor these specifical ly the detection zone can be adjusted precisely by means of shrouds The sensor lens is divided into two detection zones With one half a max reach of 5 m is achieved and with the other a max reach of 12 m for an installation height of approx 2 m After fitting the lens press lens firmly into the channel provided you will see the max rea...

Страница 5: ...air from fans or open windows Blank out areas with shrouds Blank out areas with shrouds Adjust detection zone or install in a different place Malfunction Cause Remedy Wiring examples 1 Fixture without neutral conductor 2 Fixture with neutral conductor 3 Connection via series switch for manual and automatic operation 4 Connection to double throw switch for permanent light and automatic operation Se...

Страница 6: ...max réglage de précision par caches de 1 à 12 m Temporisation 10 s 15 min Réglage de crépuscularité 2 2000 lux Classe IP 54 Declaration of conformity Functional Warranty This product complies with the European Directive on Low Voltage Appliances 73 23 EEC and the EMC Directive 89 336 EEC This STEINEL product has been manufactured with great care and its operation and safety have been tested in con...