Version 12.2022
Assembly instructions
61
12 Technical data
When using another control unit, the following limits must be set:
Limits
Motor side
Output side
Rotation speed (1/min)
8 000
4 293
Peak torque (Nm)
1.384
2.25
Peak current (A)
2.663
–
The STEINEL S-Former E control unit fulfils all the requirements pertaining to the servo controller’s output
and current.
When using another control unit, ensure that the servo controller in use is able to fulfil the continuous
and peak outputs and currents.
The expected lifetime is dependent on the application, load, ambient conditions,
general handling and maintenance.
The following lifetime specifications are empirical values. They serve for orien-
tation and information and are not obligatory.
Lifetime under optimal usage conditions
AC Servodrive
20 000 h/ 5 years
Ball bearings
20 000 h
Toothed belt
10 million cycles
Spline shaft
10 million cycles
Splined hub
5 million cycles
Cylinder
5 million cycles
Valve
5 million cycles
Содержание S-Former E
Страница 1: ...Assembly instructions for S Former E ...
Страница 91: ......